User Manual

Chapter 7 Detail View window
Amp Editor Owner’s Manual
124
Mute (TXn only)
When the amp section’s heat sink temperature indication exceeds 90%, or when a short has caused the
load to fall below 0.5 , or when the power supply has malfunctioned, or when ultra-high frequencies are
detected, the speaker output will be muted and the Mute indicator will light red. If an alert has been spec-
ified in the “Alert Setup” dialog box, the alert indicator will also light and be recorded in the log.
The temperature at 90% will differ between amplifiers. For details, refer to the owner’s manual
or reference manual of each amplifier.
Shutdown (TXn only)
When the power supply section’s temperature exceeds the power supply protection temperature of the
amplifier itself, when abnormal heating occurs, or when DC output is detected, the power supply to the
amplifier’s drive section will automatically stop, and the Shutdown indicator will light red. The alert indi-
cator will light and will be recorded in the log. In order to clear the Shutdown state, you must cycle the
power switch of the amplifier itself. (This state cannot be cleared by power supply operations from Amp
Editor.)
The power supply protection temperature will differ between amplifiers. For details, refer to the
owner’s manual or reference manual of each amplifier.
The temperature monitor meter shows only the head sink temperature of the amp section. The
temperature of the power supply section is not shown.
r Clip Limiter (TXn only)
If the Clip Limiter operates for a channel, the output from the amplifier will be compressed, and the Clip Lim-
iter indicator will turn red. If an alert has been specified in the “Alert Setup” dialog box, the alert indicator
will also light and be recorded in the log.
Mute indicator Alert indicator
Normal state: green
Muted : red
Normal state : unlit
Muted : lit
Shutdown indicator Alert indicator
Normal state : green
Shutdown : red
Normal state : unlit
Shutdown : lit
Clip Limiter indicator Alert indicator
Normal state : green
Limiting : red
Clip Limiter Off : grey
Normal state : unlit
Limiting : lit
NOTE