Service manual

ELEC
SIGNALING SYSTEM
8-35
ss
WARNING
Handle the thermo switch with special
care.
Never subject the thermo switch to
strong shocks. If the thermo switch is
dropped, replace it.
Thermo switch
16 Nm (1.6m • kg)
Three bond sealock
®
10
Does the thermo switch operate properly as
described above?
3. Voltage
Connect the pocket tester (DC 20 V) to the
meter coupler (wire harness side) as
shown.
Positive tester probe

brown
Negative tester probe

green/red
Set the main switch to “ON”.
Measure the voltage (DC 12 V) of brown
and green/red at the meter coupler.
Is the voltage within specification?
Replace the thermo
switch
The wiring circuit
from the main
switch to the meter
coupler is faulty
and must be
repaired.
LY
Br
Ch Dg
RB
Gy GR
BY Sb G LG
Dg Ch L GR Y Gy
RBrBBYSbG
RY
RYLG
Br
G
R
/
The circuit is OK.
YES
NO
YES
NO