Service manual

7 - 20
–+
ELEC
ELECTRIC STARTING SYSTEM
EB803402
YES
NO
4.Relay unit (starting circuit cutoff relay)
• Disconnect the relay unit from the cou-
pler.
Connect the pocket tester (Ω× 1) and
battery (12 V) to the relay unit terminals
as shown.
Battery positive terminal red/black 1
Battery negative terminal
black/yellow 2
Tester positive probe blue 3
Tester negative probe blue/white 4
Does the starting circuit cutoff relay
have continuity between blue and blue/
white?
Replace the relay
unit.
EB803403
YES
NO
5.Relay unit (diode)
• Disconnect the relay unit from the cou-
pler.
Connect the pocket tester (Ω× 1) to the
relay unit terminals as shown.
Check the diode for continuity as fol-
lows.
Tester positive probe
sky blue 1
Tester negative probe
black/yellow 2
Continu-
ity
Tester positive probe
sky blue 1
Tester negative probe
blue/yellow 3
Tester positive probe
black/yellow 2
Tester negative probe
sky blue 1
No conti-
nuity
Tester positive probe
blue/yellow 3
Tester negative probe
sky blue 1
Are the tester readings correct?
Replace the relay
unit.
NOTE:
When you switch the tester’s positive
and negative probes, the readings in the
above chart will be reversed.
7