Service manual
7 - 53
–+
ELEC
CARBURETOR HEATING SYSTEM
Å The thermo switch circuit is open.
ı The thermo switch circuit is closed.
Test step Water temperature
Continu-
ity
1
Less than 23 ± 3 ˚C
(73.4 ± 5.4 ˚F)
YES
2
More than 23 ± 3 ˚C
(73.4 ± 5.4 ˚F)
NO
3
More than 12 ± 4 ˚C
(53.6 ± 7.2 ˚F)
NO
4
Less than 12 ± 4 ˚C
(53.6 ± 7.2 ˚F)
YES
Test steps 1 & 2: Heating phase
Test steps 3 & 4: Cooling phase
YES
NO
• Does the thermo switch operate prop-
erly?
Replace the thermo
switch.
WARNING
WARNING
• Handle the thermo switch with special
care.
• Never subject the thermo switch to
strong shocks. If the thermo switch is
dropped, replace it.
YES
NO
5.Carburetor heater
• Remove the carburetor heater from the
carburetor.
• Connect the pocket tester to the carbure-
tor heater as shown.
Tester positive probe →
carburetor heater terminal 1
Tester negative probe →
carburetor heater body 2
• Measure carburetor heater resistance.
Carburetor heater resistance
12 V 30 W: 6 ~ 10 Ω at 20˚C (68˚F)
• Is the carburetor heater OK?
Replace the carbu-
retor heater.
7