Service manual

7 - 53
–+
ELEC
CARBURETOR HEATING SYSTEM
Å The thermo switch circuit is open.
ı The thermo switch circuit is closed.
Test step Water temperature
Continu-
ity
1
Less than 23 ± 3 ˚C
(73.4 ± 5.4 ˚F)
YES
2
More than 23 ± 3 ˚C
(73.4 ± 5.4 ˚F)
NO
3
More than 12 ± 4 ˚C
(53.6 ± 7.2 ˚F)
NO
4
Less than 12 ± 4 ˚C
(53.6 ± 7.2 ˚F)
YES
Test steps 1 & 2: Heating phase
Test steps 3 & 4: Cooling phase
YES
NO
Does the thermo switch operate prop-
erly?
Replace the thermo
switch.
WARNING
WARNING
Handle the thermo switch with special
care.
Never subject the thermo switch to
strong shocks. If the thermo switch is
dropped, replace it.
YES
NO
5.Carburetor heater
• Remove the carburetor heater from the
carburetor.
Connect the pocket tester to the carbure-
tor heater as shown.
Tester positive probe
carburetor heater terminal 1
Tester negative probe
carburetor heater body 2
Measure carburetor heater resistance.
Carburetor heater resistance
12 V 30 W: 6 ~ 10 at 20˚C (68˚F)
Is the carburetor heater OK?
Replace the carbu-
retor heater.
7