User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon and channel color
- Making HA (Head Amp) settings
- Sending a signal from an input channel to the STEREO/MONO buses
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- Output channels
- EQ and Dynamics
- Grouping and linking
- Scene memory
- About scene memories
- Using scene memories
- Editing scene memories
- Using the Global Paste function
- Using the Focus function
- Using the Recall Safe function
- Using the Fade function
- Outputting a control signal to an external device in tandem with scene recall (GPI OUT)
- Playing back an audio file that links to a scene recall
- Using Preview mode
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O device and external head amp
- MIDI
- User settings (Security)
- Recorder
- Help function
- Other functions
- About the SETUP screen
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Appendices
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Effects and tempo synchronization
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- Functions that can be assigned to USER DEFINED keys
- Functions that can be assigned to USER DEFINED knobs
- Functions that can be assigned to the assignable encoders
- MIDI Data Format
- Warning/Error Messages
- Electrical characteristics
- Mixer Basic Parameters
- M IDI Implementation Chart
- Index
User settings (Security)
Reference Manual
178
Loading a file from the USB flash drive
Follow the steps below to load CL settings file (extension .CLF) from the USB flash drive into the CL
series console.
You can use the same procedure to load the following files as well as setting files.
NOTICE
Some data may contain settings that will cause the console to output signals immediately after
the data is loaded. Therefore, before loading data, turn off the power to the equipment connected
to the CL series console and/or lower the volume of such equipment so that there will not be a
problem even if a signal is output from the CL console.
1. In the Function Access Area, press the SETUP button to access the SETUP screen.
2. Press the SAVE/LOAD button to access the SAVE/LOAD popup window.
3. To select the file that you want to load, press the name of the desired file in the file
list, or rotate the corresponding multifunction knob on the panel.
The highlighted line in the file list indicates the file that is selected for operations.
4. If you want the DANTE SETUP and I/O device-related settings saved in the CL
settings file (file name extension .CLF) to be applied to the CL console, press the
WITH DANTE SETUP AND I/O DEVICE button to turn it on.
5. Press the LOAD button. A confirmation dialog box will appear.
6. Press the OK button to begin loading the file.
When the file has finished loading, the PROCESSING popup window that shows the progress of
the loading operation will close. If you cancel this procedure while it is in progress, data up to the
cancellation point will still be loaded.
Some setting data may not be loaded, depending on the USER LEVEL setting during the load
operation.
Editing the files saved on the USB flash drive
This section explains how to perform editing operations such as sorting the files and directories on the
USB flash drive, editing the file names or comments, copying, and pasting.
■ File editing
1. In the Function Access Area, press the SETUP button to access the SETUP screen.
2. Press the SAVE/LOAD button to access the SAVE/LOAD popup window.
The list will show the files and sub-directories that have been saved.
1 COPY button
Copies a file into buffer memory (a temporary holding area).
2 PASTE button
Pastes the file from buffer memory.
3 DELETE button
Deletes the selected file or directory.
NOTE
A directory cannot be deleted unless it is empty. The message “Directory Not Empty!” will appear.
Extension Type Contents of file
.CLF ALL CL console internal setting file
.CLU KEY CL console user authentication key
.XML XML XML file for displaying Help
.TXT TEXT Text file for displaying Help
.BMP BMP
Image file for display in the CONSOLE LOCK screen (256 or more
colors, uncompressed bitmap format)
1 2 3 45 6
7
8 9 0 A BC