8. Repeat steps 6–7 to adjust the faders for positions 1 through 4.
After the positions are corrected, automatic motorized calibration will start.
9. When calibration is complete and if the RESTART button has not appeared, press
the APPLY button.
The calibration settings will be saved in internal memory. If the RESTART button appears,
calibration has failed. Press the RESTART button to execute calibration once again.
10. Press the EXIT button.
The CL unit will start up in normal operating mode.
NOTE
Alternatively, you can continue operation by selecting a different menu instead of pressing the
EXIT button.
Fine-tuning the input and output gain (Calibration
function)
If necessary, you can make fine adjustments to the input and output gain.
1. While holding down the SCENE MEMORY [STORE] key on the panel, turn on the
power to the CL unit.
After the opening screen, the following startup menu screen will appear.
2. In the MODE SELECT field, select the item you want to adjust, and then press the
button.
The corresponding setting screen will appear.
You can make the following three gain adjustments for analog input and output.