User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon and channel color
- Making HA (Head Amp) settings
- Sending a signal from an input channel to the STEREO/MONO buses
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- Output channels
- EQ and Dynamics
- Grouping and linking
- Scene memory
- About scene memories
- Using scene memories
- Editing scene memories
- Using the Global Paste function
- Using the Focus function
- Using the Recall Safe function
- Using the Fade function
- Outputting a control signal to an external device in tandem with scene recall (GPI OUT)
- Playing back an audio file that links to a scene recall
- Using Preview mode
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O device and external head amp
- MIDI
- User settings (Security)
- Recorder
- Help function
- Other functions
- About the SETUP screen
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Appendices
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Effects and tempo synchronization
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- Functions that can be assigned to USER DEFINED keys
- Functions that can be assigned to USER DEFINED knobs
- Functions that can be assigned to the assignable encoders
- MIDI Data Format
- Warning/Error Messages
- Electrical characteristics
- Mixer Basic Parameters
- M IDI Implementation Chart
- Index
Appendices
Reference Manual
260
EFFECT
BYPASS
EFFECT RACK1–8
PREMIUM RACK1A
PREMIUM RACK1B
:
PREMIUM RACK8A
PREMIUM RACK8B
GAIN KNOB
FUNCTION
LATCH —
Toggle the function of the GAIN knob
(ANALOG GAIN/DIGITAL GAIN). Lit when
DIGITAL GAIN is selected.
UNLATCH —
Assign the function of the GAIN knob
(ANALOG GAIN/DIGITAL) to DIGITAL GAIN
only while held down.
* However if the GAIN KNOB FUNCTION is
switched to DIGITAL GAIN in the PREFERENCE
screen etc., this will remain lit until the next
time it is pressed.
GEQ FREQ
BANK
INC
—
Adds or removes a frequency bank in the GEQ
EDIT screen.
DEC
GPI OUT
LATCH
PORT1–PORT5
Toggle the GPI OUT function. Lit when active.
UNLATCH Make GPI OUT active only while pressed.
HELP — —
Opens and closes the HELP pop-up window.
Operating the controllers on the panel
(excluding faders), or controllers on the screen,
while holding down this key will display the
related information.
HOME
SELECTED CH VIEW — Displays the SELECTED CHANNEL VIEW screen.
OVERVIEW — Displays the OVERVIEW screen.
TOGGLE —
Each press of the key will alternately display the
SELECTED CHANNEL VIEW screen and the
OVERVIEW screen.
METER PEAK HOLD ON —
Turns the meter’s peak hold function on/off. Lit
when on.
MIDI
PROGRAM CHANGE PGM 0–128
Transmit the corresponding MIDI message.
CONTROL CHANGE
CC 1–31, 33–95,
102–119
NOTE ON
NOTE ON C-2 (0)
:
NOTE ON G 8 (127)
FUNCTION PARAMETER 1 PARAMETER 2 Explanation
MONITOR
OUTPUT — Switch MONITOR on/off.
SELECTED CH ASSIGN —
While holding down this key, press the SEL key
of a MIX or MATRIX channel to switch the
assignment on/off. During this time, the [SEL]
LED will be lit if assign is ON, or dark if OFF.
The assignment setting made while holding
down this key will be stored. Pressing the key
again will recall the stored setting. Settings can
be stored in multiple keys to facilitate rapid
assignment switching.
SOURCE SELECT
STEREO L/R
Recall the selected signal to the monitor.
MONO(C)
LCR
PB OUT
OMNI1-2
OMNI3-4
OMNI5-6
OMNI7-8
DEFINE
MUTE
MASTER
MUTE GROUP 1
— Switch MUTE GROUP MASTER on/off.:
MUTE GROUP 8
ALL MUTE —
Turns all MUTE GROUP MASTER settings on/off
together.
NUENDO
LIVE
TRANSPORT
GO TO PROJECT START
Operate the transport functions of Nuendo
Live.
GO TO PREV MARKER
REWIND
FAST FORWARD
GO TO NEXT MARKER
GO TO PROJECT END
CYCLE
STOP
START
REC
EASY RECORDING
PEAK CLEAR —
Clear the peak indicators of the Nuendo Live
screen.
OSCILLATOR
OSCILLATOR ON — Switch the OSC on/off.
SELECTED CH ASSIGN —
While holding down this key, press a SEL key of
a channel to switch the assignment on/off.
During this time, the [SEL] LED will be lit if
assign is ON, or dark if OFF.
DIRECT ASSIGN *1)
Assign the oscillator to the channel selected
from list 1).
FUNCTION PARAMETER 1 PARAMETER 2 Explanation