User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon and channel color
- Making HA (Head Amp) settings
- Sending a signal from an input channel to the STEREO/MONO buses
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- Output channels
- EQ and Dynamics
- Grouping and linking
- Scene memory
- About scene memories
- Using scene memories
- Editing scene memories
- Using the Global Paste function
- Using the Focus function
- Using the Recall Safe function
- Using the Fade function
- Outputting a control signal to an external device in tandem with scene recall (GPI OUT)
- Playing back an audio file that links to a scene recall
- Using Preview mode
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O device and external head amp
- MIDI
- User settings (Security)
- Recorder
- Help function
- Other functions
- About the SETUP screen
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Appendices
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Effects and tempo synchronization
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- Functions that can be assigned to USER DEFINED keys
- Functions that can be assigned to USER DEFINED knobs
- Functions that can be assigned to the assignable encoders
- MIDI Data Format
- Warning/Error Messages
- Electrical characteristics
- Mixer Basic Parameters
- M IDI Implementation Chart
- Index
Scene memory
Reference Manual
96
Using Preview mode
Preview mode lets you view or edit the settings of a scene stored in memory without affecting the signal
processing of the current scene. When you recall a scene in this mode, the settings of the newly recalled
scene will appear on the panel of the CL series console, but the signal processing of the current scene
will remain as it was prior to the recall. Even if you modify the settings and save them as a new scene
or by overwriting, the signal processing of the current scene will remain as it was prior to the recall.
During an actual performance, it can be convenient to use this to check the content of the scene you
intend to recall next, or to make minor changes to a scene and then store it.
1. Press the PREVIEW button on the panel or the PREVIEW button in the SCENE LIST
window.
The PREVIEW button will light, and the console will be in Preview mode.
In this state, operating controllers such as the knobs and faders will not affect the signal
processing of the current scene.
2. Use the SCENE MEMORY [INC]/[DEC] keys to select the scene number that you
want to recall.
3. Press the SCENE MEMORY [RECALL] key. To execute the Recall operation, press the
OK button.
The scene will be recalled. However, the internal signal processing of the current scene will
remain unchanged as it was prior to the Recall operation.
If desired, you can access a specific channel in the SELECTED CHANNEL section, or access a
specific screen in the display to examine the values in detail.
4. If desired, use the panel controls to edit the settings.
Operating a panel control in Preview mode will edit the settings of the scene you recalled in step
3, but will not affect the signal processing of the current scene.
5. If you want to store the changes you made in step 4, select the scene number in
which you want to store the scene, and press the SCENE MEMORY [STORE] key.
The settings you edited in step 4 will be stored into memory.
6. When you have finished viewing or editing the settings of the scene, press the
PREVIEW button of the panel or the PREVIEW button in the SCENE LIST window.
The PREVIEW button will go dark; the CL series console will exit Preview mode and return to
the normal state.
NOTE
PREVIEW mode applies to all parameters included in scene memory, all parameters included in
the INPUT PATCH and OUTPUT PATCH functions, and HA parameters.
Functions in Preview mode
The current scene will be modified by the following software and external operations.
•CL Editor
•Stage Mix
• MIDI Rx
•GPI IN
Similarly, edits for the current scene will be conveyed to the following software and external devices.
•CL Editor
•Stage Mix
• MIDI Tx
•GPI OUT
The meters will indicate the state of signal processing for the current scene.
Playback Link will operate for recalling the current scene.
If cascade-connected, both master and slave units will operate independently. Link will not occur while
in Preview mode.
The following functions will not operate in Preview mode.
• Synchronization with CL Editor
• Switching users
• Changing the User Level
• Load/Save functions
•Cue changes
•USER DEFINED KEYS operations
•USER DEFINED KNOB operations
• Monitor (MONITOR, CUE, OSCILLATOR, TALKBACK) changes or display
• Changing or viewing Nuendo Live settings
• Changing or viewing the recorder
• Changing DANTE SETUP or DANTE PATCH settings
• FADE TIME
• EFFECT FREEZE playback or recording
• MIDI clock and tap tempo for effects
• Internal metering for Premium Effects (GR for DynamicEQ and Portico 5043; VU for Opt-2A and
U76)
In addition, you cannot enter Preview mode while performing the following operations.
• While pasting scene or EQ settings.
• While executing Global Paste
• While synchronizing with CL Editor
• While saving/loading a file