SIGNAL SYSTEM
5. VOLTAGE
• Connect the Multimeter (DC20V) to the
Bulb Socket connector
Turn the Main Switch to ‘ON’
Turn the Turn Switch to left or right
Check for voltage (12V) on the “Chocolate”
lead and “Dark green” at the Flasher Light
terminal.
At flasher light (LH)
Multimeter (+) lead Ÿ Chocolate Terminal ¿
Multimeter (-) lead Ÿ Body earth Á
At flasher light (RH)
Multimeter (+) lead Ÿ Dark Green Terminal À
Multimeter (-) lead Ÿ Body earth Á
MEETS
SPECIFICATIONS
Wiring connection
Wiring circuit from the Turn Switch to Bulb
Socket connector is faulty. Repair/Replace
Refer to “CIRCUIT DIAGRAM”.
OUT OF SPECIFICATION
This circuit is O.K.
4. FLASHER RELAY
• Connect the Multimeter (DC20V) to the
flasher relay coupler
Turn Main switch to ‘ON’
Check for voltage (12V) on “Brown/White”
lead at Flasher Relay and (-) terminal body
earth
Multimeter (+) lead Ÿ Brown/White Terminal
¿
Multimeter (-) lead Ÿ Black Terminal À
MEETS
SPECIFICATION
OUT OF SPECIFICATION
The Flasher Relay is faulty. Replace.
7-19