Specifications

INSP
ADJ
L-46
VALVE CLEARANCE CHECKING AND ADJUSTMENT
ææææææææææææææææææææææææææææææææææ
Checking steps :
Measurement steps :
Rotate the Crankshaft anticlockwise to align
the slit ç third mark on the rotor with the sta-
tionary pointer è on the Crankcase Cover LH
when the Piston is at Top Dead Center (T.D.C.)
and in compression stroke.
Measure the Valve clearance by using a feeler
gauge.
Out of specification Ÿ Adjust clearance.
ææææææææææææææææææææææææææææææææææ
5. Adjust :
Valve clearance
ææææææææææææææææææææææææææææææææææ
Adjustment steps :
Loosen the Locknut ¿
Turn the Adjuster À in or out with the Valve
adjusting tool Á until specified clearance is
obtained.
Hold the Adjuster to prevent it from moving
and tighten the Locknut.
Measure the Valve clearance.
If the clearance is incorrect, repeat above
steps until specified clearance is obtained.
ææææææææææææææææææææææææææææææææææ
3-7
6. Install
Timing Check Plug (with O-ring ) ¿
Center Plug (with O-ring) À
Turning in ŸValve clearance is decreased.
Turning outŸValve clearance is increased.
Feeler Gauge
YSST 615
Valve adjusting tool :
YSST - 606
Locknut :
8 Nm (0.8 m • kg, 5.8 ft • lb)