User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Remount function to USB flash drives
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Setup
V5 Reference Manual
246
• 32bit................... This is effective when transmitting and receiving 25-bit or larger data
(when using cascade or gain compensation), but the amount of data
being transmitted will increase 20-30% compared to 24-bit.
7 LATENCY select buttons
Enable you to set the Dante audio network latency to 0.25 ms, 0.5 ms, 1.0 ms, 2.0 ms,
or 5.0 ms.
The latency setting varies depending on the network connection method and size. For
details, refer to “Setting the Dante audio network latency” (page 249).
8 DANTE PATCH BY select buttons
If the THIS CONSOLE button is selected, the DANTE INPUT PATCH and DANTE OUTPUT
PATCH settings can be edited from the QL series console.
If the DANTE CONTROLLER button is selected, it will not be possible to edit the Dante
patch settings. You can operate these buttons regardless of the state of the DANTE
PATCH BY select buttons on other CL/QL series consoles on the network.
9 PREFERRED MASTER button
If this button is turned ON, the console’s status as a master is given greater priority in
the Dante audio network.
If this button is turned OFF, the console’s status as a master is given less priority in the
Dante audio network.
• If there is only one QL console for which this button is turned ON, that console will become the
master.
• If there are multiple QL consoles for which this button is turned ON, only one of them will become
the master.
• If this button is turned OFF for all QL consoles, one unit out of all Dante devices, including I/O
devices, will become the master.
NOTE
• Settings that are shared with the I/O device (BIT/LATENCY/W.CLOCK) will reflect the settings of
the QL series console whose CONSOLE ID is set to #1.
• If the DANTE CONTROLLER button is selected in the DANTE PATCH BY section, and you
attempt to edit the Dante patching or related settings, the message “This Operation is Not
Allowed” will appear at the bottom of the screen.
• DANTE patch information is applied to the device if the QL settings file (file name extension .CLF)
is loaded under the following conditions. Otherwise, the information is not applied and the current
state will be maintained.
• In the SAVE/LOAD window (page 227), the WITH DANTE SETUP AND I/O DEVICE button is
on.
• Either #1, #2, #3, or #4 CONSOLE ID select button is on.
• The THIS CONSOLE button of the DANTE PATCH BY select buttons is on.
• With QL V1.07 and later, when settings are initialized, including Dante audio network settings, or
a firmware update is installed, the Preferred Master setting is turned on. This setting is not
changed when console settings are changed or when the console is restarted. It can be turned
off using the Dante Controller, if necessary. If this default setting is used to change CL or QL word
clock settings for anything other than Dante, that console is given priority as the clock master for
the Dante network to prevent clock synchronization errors. Further, you can use Dante Controller
to clearly specify the master by turning on only Preferred Master for the device that will always be
running (off for all other devices).
Dante Device Lock
Dante Device Lock prevents changes to the Dante audio network settings of a Dante device
by another computer on the same network. Dante Device Lock settings are configured in
Dante Controller.
When Dante Device Lock is enabled on a QL console, the following parameters cannot be
changed.
• CONSOLE ID
• SECONDARY PORT
•BIT
• LATENCY (ms)
• PREFERRED MASTER
When Dante Device Lock is enabled on a QL console, the DANTE DEVICE LOCKED indicator
lights up in red on the top left side of the DANTE SETUP window.
If you try to change any of these parameters, the following message will appear at the bottom
of the window.