User Manual

Setup
V5 Reference Manual
257
Warning messages
The indicators will remain lit/blinking cyclically until the problem has been resolved.
If the green [SYNC] indicator is not lit, the devices word clock is not defined.
If the green indicator is blinking, the unit is operating as the word clock master.
If the green indicator lights, the unit is operating as a word clock slave and synching to the
word clock.
The positions of the device
setting DIP switches do not
match the actual Dante settings.
If the Device Lock setting was
enabled from Dante Controller or
if the device is set to READ ONLY
in DDM mode, disable the setting.
Check the device setting DIP
switch positions, and set them to
accommodate the current
situation.
Power supply problem has
occurred on Rio3224-D2/
Rio1608-D2.
Check whether power is supplied
correctly to the AC IN connectors
A and B respectively.
[SYNC] indicators Meaning Possible solution
The word clock is not set
correctly.
Set the word clock master and the
sampling frequency correctly on
the QL5/QL1-native device or in
Dante Controller.
Dante Network circuit is
broken.
Make sure that the Ethernet
cables are not removed or short-
circuited.
Dante Network is connected
incorrectly. Other Dante
devices cannot be found.
Make sure that the Ethernet
cables are connected correctly.
[SYSTEM] indicators Meaning Possible solution
Lit
Lit
Blinking
Flash x2
Flash x3
[SYNC] indicators Meaning Possible solution
A non-GbE-compatible device
is connected.
If audio is transmitted over the
Dante network, use a GbE-
compatible device.
The SECONDARY connector
has taken over
communications during
redundant network operation.
Check the circuit connected to the
PRIMARY connector.
An abnormality has occurred
on the circuit connected to the
SECONDARY connector
during redundant network
operation.
Check the circuit connected to the
SECONDARY connector.
Lit
Lit or
blinking
Blinking
Lit or
blinking
Flash x2
Lit or