A KEY IN SOURCE select button
Press this button to display the KEY IN SOURCE SELECT window, in which you can select
a key-in signal that will trigger the dynamics.
• SELF PRE EQ ....................... The pre-EQ signal of the same channel.
• SELF POST EQ..................... The post-EQ signal of the same channel.
• MIX OUT 13–16 ..................... Output signals of MIX channels 13–16
• CH1–64 POST EQ (QL5), CH1–32 POST EQ (QL1), ST IN1L–8R POST EQ,
MIX1–16 POST EQ, MTRX1–8 POST EQ, ST L/R, MONO POST EQ
........................ The post-EQ signal of the corresponding channel
*1
*1. The selectable signals are limited to the corresponding eight-channel group.
NOTE
In the case of QL1, channels that do not exist on the model will not be shown.
B KEY IN FILTER parameter area (Displayed only for Dynamics 1 for an input
channel)
Enables you to make various settings for a filter that lets the key-in signal pass.
• Filter select buttons ............. Select the type of filter from HPF, BPF, or LPF. To
disable the filter, press the button that is turned on.
• Q knob................................... Indicates the filter Q. You can use the [TOUCH AND
TURN] knob to adjust the value.
• FREQUENCY knob ............... Indicates the filter cutoff frequency. You can use the
[TOUCH AND TURN] knob to adjust the value.
C KEY IN CUE button (Displayed only for Dynamics 1 for an input channel)
Enables you to cue-monitor the signal that has been selected as the KEY IN SOURCE
signal. Cue will be canceled if you have selected a dynamics type that does not feature
this button, or if you move to a different screen.
NOTE
The cue monitoring does not support CUE B.
D Tabs
Use these tabs to select a channel that you want to view on the screen.
DYNAMICS1/2 window (8ch)
This window displays the input channel or output channel dynamics settings in groups of 8
channels simultaneously. This window is convenient if you want to adjust the threshold or
certain other parameters while watching the adjacent channels to the left and the right.
1 Channel select button
Selects the channel that you want to control. The current channel icon and number
appear on the button, and the channel name appears immediately below the button.
2 DYNAMICS OUTPUT meters, GR meter
Indicate the output levels of signals after dynamics processing, and the amount of gain
reduction. If GATE is selected as the dynamics type, a three-step indicator appears,
indicating the open/close status of the gate.
If GATE is selected as the dynamics type, the indicator status means the following:
Gate status
Red Yellow Green Off (dark)
On/Off status On On On Off
Open/Close
status
Close Open Open —
Amount of gain
reduction
30 dB or more less than 30 dB 0 dB —
1
2
4
5
3
Type = Any type other than GATE