Library link HA & Channel Name (in Input Patch/Output Patch libraries)
In the case of PM5D, HA parameters belong to HA library, and Channel names belong to
Input Patch and Output Patch library.
In the case of M7CL, both HA and Channel names belong to Scene library.
This difference is treated as described below, on an assumption of sequential recall from the
smallest Scene number in the conversion target range to the largest number.
> Conversions from PM5D to M7CL:
When a PM5D’s Scene has link(s) with HA/Input Patch/Output Patch, HA parameters,
Input channel names and Output channel names in the linked libraries are converted
into the same numbered M7CL Scene.
When a PM5D’s Scene doesn’t have link(s) with HA/Input Patch /Output libraries, HA
parameters, Input channel names and Output channel names remain as in the
previous numbered Scene.
All Focus settings in the M7CL Scenes are enabled.
An example of sequential Scene conversion from PM5D to M7CL.
> Conversions from M7CL to PM5D:
File Converter creates a new PM5D Scene with links to HA/Input Patch/ Output Patch
libraries.
When HA parameters, Input channel names or Output channel names are edited from
the previous Scene in M7CL, this converter creates new HA/Input Patch/Output Patch
library settings, with links to the new Scene in PM5D.
When the HA parameters, Input channel names or Output channel names are the
same as the previous Scene in M7CL, this converter only creates a library link
between the latest created HA/Input Patch/Output Patch settings and the new Scene
in PM5D.
HA library001
Scene library001
Input Patch library001
Output Patch library001
link
link
link
Scene 001
001
001
001
001
001
HA library 004
Scene library002
Input Patch library003
link
link
Scene 002
002
002
004
003
001
PM5D
M7CL
Scene library003
Scene 003
003
003
004
003
001
Ch name
Ch name
Ch name