User Manual

Using the Monitor function
143
M7CL Owner’s Manual
Monitor/Cue
13
C TALKBACK DIMMER field
Here you can view and make settings for the Talkback
Dimmer.
•TALKBACK DIMMER knob
...........This adjusts the amount by which
the monitor signal will be attenuated
when talkback is on. You can use
multifunction encoder 5 to control
this. This operation can also be per-
formed in the TALKBACK DIMMER
field of the MONITOR screen.
•TALKBACK DIMMER indicator
...........This indicator shows that talkback is
on, and that the talkback dimmer is
operating.
D MONITOR DELAY field
This field specifies the monitor delay setting by which
the monitor signal is delayed. You can use this in large
auditoriums where there is a time difference between
the monitor signal and the direct sound.
MONITOR DELAY knob
...........Adjusts the delay time for the moni-
tor signal. You can use multifunction
encoder 6 to control this.
MONITOR DELAY ON button
...........If this button is on, the monitor sig-
nal will be delayed according to the
setting of the MONITOR DELAY
knob.
E MONO MONITOR button
This button allows monaural monitoring. If this button
is on, the signal sent from the PHONES OUT jack and
the MONITOR OUT L/R channels will be monaural.
F PHONES LEVEL LINK button
If this is on, the MONITOR LEVEL knob will adjust
the level of the signal sent to the PHONES OUT jack.
G OUTPUT button
Switches the monitor function on/off. This operation
can also be performed using the OUTPUT button in
the MONITOR screen.
H Meter field
Output select button
...........This opens the OUTPUT PORT
SELECT popup window, where you
can select the port that will output
the monitor signal.
•Level meter ....This indicates the level of the moni-
tor signal. This meter shows the
level immediately before the dimmer.
I ASSIGN field
If you selected DEFINE in the SOURCE SELECT
field, use this field to specify the monitor source. You
can select up to eight monitor sources simultaneously.
Pressing the CLEAR ALL button will clear all selec-
tions.
4
Use the buttons of the SOURCE SELECT
field to select a monitor source.
In the SOURCE SELECT field you can select only
one monitor source. However if you’ve selected
DEFINE, you can use the ASSIGN field to specify
multiple monitor sources.
The following table shows the monitor sources you
can select in the SOURCE SELECT field.
If you’ve selected DEFINE in the SOURCE SELECT
field, you can use the ASSIGN field to select multiple
sources. The following table shows the monitor
sources you can select in the ASSIGN field.
5
To specify a port as the output destination
for monitor signals L, C, R, press one of the
output select buttons (L/R/C) in the meter
field to open the OUTPUT PORT SELECT
popup window, and choose from the follow-
ing monitor signal output destinations
(multiple selections are allowed).
When you’ve selected an output port, press the
CLOSE button to close the popup window.
In the same way, specify the output ports for MONI-
TOR OUT L, R, and C.
If the normal dimmer and the talkback are both switched on
simultaneously, the setting with the greatest amount of atten-
uation will be applied.
HINT
STEREO L/R button STEREO L/R channel output signal
MONO (C) button MONO channel output signal
LCR button
STEREO L/R + MONO channel (LCR)
output signal
ST IN 1–4 buttons ST IN jacks 1–4 input signals
DEFINE button
The signal(s) selected in the ASSIGN
field
MIX 1–16 buttons Output signals of MIX channels 1–16
MTRX 1–8 buttons
Output signals of MATRIX channels 1–8
STEREO L/R button STEREO L/R channel output signal
MONO (C) button MONO channel output signal
ST IN 1–4 buttons ST IN jacks 1–4 input signals
OMNI 1–16 OMNI OUT jacks 1–16
2TR OUT L, R 2TR OUT DIGITAL jack L, R
SLOT 1–3
Output channels 1–16 of an I/O card
installed in slots 1–3
•You can select a maximum of eight monitor sources in the
ASSIGN field. If you select eight monitor sources, no further
selections will be possible. Please turn off the buttons for
unneeded sources.