User Manual

4
[OUTPUT CHANNEL LIBRARY]
1
CURRENT TYPE
(OUTPUT CHANNEL LIBRARY only)
Displays the type of channel selected by the [SEL] key.
B
Library type (OUTPUT CHANNEL LIBRARY only)
Displays the type of channel for the library item in the list.
C
Library list
Selects the library item that will be the object of the opera-
tion. The selected library item will move to the center, and
will be highlighted.
D
STORE button
Stores the settings of the currently selected channel into the
selected location of the list. When you press this button, the
LIBRARY STORE window will appear, allowing you to
name the settings.
E
RECALL button
Recalls the settings shown in the list into the currently
selected channel.
F
CLEAR button
Clears (deletes) the library item selected in the list. When you
press this button, a dialog box will ask you to confirm the
Clear operation.
4
By turning any one of the multifunction
encoders, move the highlighted line in the
list to select the library number you want to
store, recall, or clear.
5
Press the STORE button, RECALL button,
or CLEAR button.
The rest of the steps are the same as for other libraries.
You can now select POST ON (immediately after the
fader and [ON] key) as the insert or direct output position
for input/output channels.
If a rack in which a GEQ is mounted is specified as the
insert-out or insert-in, the other patch point will automati-
cally be assigned to the same rack. At the same time,
insertion is now automatically turned on. Additionally, if
you defeat the insert-out or insert-in of a rack in which a
GEQ is mounted, the other patch point will automatically
be defeated, and insertion will automatically be turned off.
The minimum threshold level for an input channel GATE
is now -72 dB.
1
2
3
4 5 6
•For the output channel library, if the type of channel selected
by the [SEL] key differs from the type of channel selected in
the list, an indication of “CONFLICT” is shown at the right of
CURRENT TYPE. Recall can be executed even if the “CON-
FLICT” indication is shown, but since the constituent parame-
ters will be different, parameters that do not exist in the library
will be set to their default values.
NOTE
If you recall to a channel that is channel-linked, linking will be
cancelled for the recalled channel.
NOTE
POST ON added as an insert /
direct out position
Insert is automatically turned
on/off when GEQ insertion is enabled
or cancelled
Changed minimum value of the
GATE threshold level
m7cl_v2_en.fm Page 4 Thursday,June 25, 2009 5:16 PM