[Remove] Button
Deletes the selected device from the list. If the removed device is not the lowest device in the list, all
devices below the removed device will be shifted upward to maintain the continuity of the list.
[Remove ALL] Button
Deletes all devices from the list.
[Undo] Button
This button provides a one-step undo function that allows you to undo a single operation and revert to the
previous state. The [Undo] button will be grayed out and inaccessible immediately after an undo
operation or after the control panel is launched.
2 Device Information
When a device that is registered for communication with the DME-N Network Driver is selected in the Target
Device List, the communication parameters for that device can be viewed and edited in the Device
Information fields.
Device Name
This is the name of the device selected in the Target Device List. The initial default settings are “UNIT1”
through “UNIT256,” but the name can be edited as required in the Device Name field.
Device IP Address
The IP address of the device selected in the Target Device List can be set via these fields. Refer to the
manual of the corresponding device for details on checking and setting its IP address.
NOTE The IP address must be set properly or communication with the device will not be possible.
Device MAC Address
The MAC (Media Access Control) address of the device can be set via these fields. The MAC address of
each device is permanently assigned when the device is manufactured and cannot be changed. The
MAC address parameter is included to prevent data from being sent to the wrong device if the IP
address in inadvertently set incorrectly. Refer to the manual of the corresponding device for details on
checking its MAC address.
NOTE The MAC address must be set properly or communication with the device will not be possible.
NOTE The MAC address of the connected device cannot be changed.
Device Port No.
The MIDI port number of the device selected in the Target Device List can be set via this menu. The MIDI
port number also functions as device ID number. It should be set to “1” for M7CL/LS9/DSP5D.
NOTE The MIDI port number must be set properly or communication with the device will not be possible.
[Apply] Button
Click the [Apply] button after editing the Device Name, Device IP Address, Device MAC Address, or
Device Port No. parameters to actually apply the changes. Also, devices added to the Target Device List
(1) by pressing the [New] or [Duplicate] buttons will only actually be registered for communication with
the DME-N Network Driver when the [Apply] button is pressed.
3 [Advanced Settings] Button
Opens the “Advanced Settings” dialog box.
This window provides access to advanced settings. For details refer to the “Advanced Setup” section.
4 [Save and Close] Button
Click the [Save and Close] button to close the “DME-N Network Driver” dialog box and save the settings.This
button is not accessible while an application that is using the DME-N Network Driver is running.
NOTE Click the [Cancel] button if you want to close the window without saving any changes.