User Manual

MIDI-Datenformat
283
M7CL – Bedienungsanleitung
Anhänge
1.4 PROGRAM CHANGE (Cn)
Reception
If [Program Change ECHO] is ON, bank select messages will also be echoed
from MIDI OUT.
If SINGLE CH is selected, these messages are received if [Program Change RX]
is ON and the [Rx CH] matches. However if [OMNI] is ON, these messages are
received regardless of the channel. When these messages are received, scene
memory and effect library are recalled according to the settings of the [Program
Change Table].
Transmission
If [Program Change TX] is ON, these messages are transmitted according to the
[Program Change Table] settings when scene memory and effect library are
recalled.
If SINGLE CH is selected, these messages are transmitted on the [Tx CH]
channel.
If the recalled scene memory and effect library has been assigned to more than
one program number, the lowest-numbered program number for each MIDI
channel will be transmitted.
Program Change messages are not used for transmission to M7CL Editor
because there is no guarantee that the contents of the assignment tables will
match. (Parameter Change messages are always used.)
You can choose either MULTI MIDI CH or SINGLE CH.
If SINGLE is selected
You can choose the RX CH, OMNI CH, and TX CH.
You can choose whether a bank select message will be added.
A bank of up to 16 can be specified.
If MULTI is selected
The RX and TX channels will be the same.
The assignment table will use the settings for each MIDI channel. Bank select
messages will not be added.
You can make settings for up to sixteen MIDI channels.
2 SYSTEM REALTIME MESSAGE
2.1 TIMING CLOCK (F8)
Reception
This message is used to control effects. This message is transmitted twenty-four
times per quarter note.
Echoing of this message depends on the OTHER item in the ECHO settings.
2.2 ACTIVE SENSING (FE)
Reception
Once this message has been received, MIDI communication will be initialized
(e.g., Running Status will be cleared) if no message is received for an interval of
400 ms.
This message is not subject to echoing.
2.3 SYSTEM RESET (FF)
Reception
When this message is received, MIDI communication will be initialized (e.g.,
Running Status will be cleared).
This message is not subject to echoing.
3 System Exclusive Message
3.1 Bulk Dump
The M7CL uses the following data types for a bulk dump.
,M‘
0–300 Szenennummer
512 Aktuelle Daten (ohne Recall Safe)
768 Aktuelle Daten (mit Recall Safe)
,S‘
512 Setup Memory
513 Mischpulteinstellung
514 Ausgangs-Port
515 Monitor
516 MIDI-Einstellung
517 Library-Nummer
,s‘
512–515 Anwenderdefinierte Tasten 1–4
516–519 Anwenderdefinierte Tasten (Gast) 1–4
520-523 Anwenderdefinierte Tasten (Admin) 1–4
524 Preference
525 Anwenderdefinierte Taste
526 Anwenderdefinierte Taste Gast
527 Preference Gast
528 Preference Admin
,Y‘
1–199 Library-Nummer
512–559 Dynamik 1 Eingänge 1–48
560–567 STIN 1L–4R
768–783 MIX 1–16
1024–1031 MATRIX 1–8
1280–1282 STEREO L,R,MONO(C)
1536-1583 Dynamik 2 Eingänge 1–48
1584–1591 STIN 1L–4R
,H‘
0–199 Library-Nummer
512–559 Eingänge 1–48, 560–567 STIN 1L–4R
,h‘
0–199 Library-Nummer
768–783 MIX 1–16
1024–1031 MATRIX 1–8
1280–1282 STEREO L,R,MONO(C)
,Q‘, ,q‘
1–199 Library-Nummer
512–559 Eingänge 1–48, 560–567 STIN 1L–4R
768–783 MIX 1–16
1024–1031 MATRIX 1–8
1280–1282 STEREO L,R,MONO(C)
,F‘
1–199 Library-Nummer
512–527 RACK 1A–8B
,E‘
1–199 Library-Nummer
512–515 RACK 5–8
,P‘, ,C‘
512 Aktuelle Daten
Data is lost when you write to the preset library.
The unique header (Model ID) identifies whether the device is a M7CL.
To calculate the check sum, add the bytes starting with the byte after BYTE
COUNT (LOW) and ending with the byte before CHECK SUM, take the binary
complement, and set bit 7 to 0.
CHECK SUM = (-sum)&0x7F
Bulk Dumps can be received at any time, and can be transmitted at any time
when a Bulk Dump Request is received.
A Bulk Dump is transmitted on the [Rx CH] channel in response to a Bulk
Dump Request.
In the data portion, seven words of 8-bit data are converted into eight words of
7-bit data.
STATUS 1100nnnn Cn
Program change
DATA 0nnnnnnn nn
Program number (0-127)
STATUS 11111000 F8
Timing clock
STATUS 11111110 FE
Active sensing
STATUS 11111111 FF
System reset
Command rx/tx function
F0 43 0n 3E BB BB 11 D0 D1 D2 …
EE F7 BULK DUMP DATA
rx/tx
BULK DUMP
DATA
F0 43 2n 3E 11 D0 D1 D2 F7
BULK DUMP REQUEST
rx
BULK DUMP
REQUEST
Data name
(D0)
Data Number
(D1,2)
tx/rx function
,M‘ 0–300, 512, 768
tx/rx
Szenenspeicher & Anforderung
(Request)
,S‘ 512–517
tx/rx
Szenenspeicher & Anforderung
(Request) (aktuelles Setup)
,s‘ 512–528
tx/rx
User-Setup-Speicher &
Anforderung (Request)
,Y‘ 1–199, 512–
tx/rx
Dynamik-Library & Anforderung
(Request)
,H‘ 0–199, 512–559,
560-567
tx/rx
Eingangskanalbibliothek &
Anforderung (Request)
,h‘ 0–199, 768–783,
1024–1031,
1280–1282
tx/rx
Ausgangskanalbibliothek &
Anforderung (Request)
,Q‘ 1–199, 512–
tx/rx
Eingangs-EQ-Bibliothek &
Anforderung (Request)
,q‘ 1–199, 768–
tx/rx
AusgangsEQ-Bibliothek &
Anforderung (Request)
,F‘ 1–199, 512– 527
tx/rx
GEQ-Bibliothek & Anforderung
(Request)
,E‘ 1–199, 512– 515
tx/rx
Effekt-Library & Anforderung
(Request)
,P‘ 512
tx/rx
Programmwechseltabelle &
Anforderung (Request)
,C‘ 512
tx/rx
Controller-Tabelle & Anforderung
(Request)