User Manual
Table Of Contents
- Contents
- Connections
- Setup Mode (Advanced settings)
- Setup Mode Operation Procedure
- Indication of Parameter Settings
- Operation Procedure
- Turning Off the Microphone Input High-Pass Filter
- Applying Compressor to the Microphone Input
- Applying EQ (equalizer) to the Input Signal
- Applying Echo/Reverb to the Input Signal
- Adjusting the Reverb Mix Level
- Adjusting the Ducker Sensitivity
- Regulating BGM Volume (Leveler)
- Setting the Chime Volume
- Adjusting the Line Out Volume by Using the [VOLUME] Knob
- Microphone Feedback Suppressor
- Initializing the settings via connected controll panels (DCP Setup)
- List of DIP Switch Settings
- Appendix
- Technical Specifications
Setup Mode (Advanced settings)
10
MA2120 Setup Guide
Applying EQ (equalizer) to the Input Signal
A two-band EQ (TREBLE and BASS) can be applied to the input signal to adjust the sound quality.
The EQ range is ±10dB and can be set in intervals of 1dB.
1 Press and hold the [SETUP] encoder for at least
one second.
2 Press input level knob 3 (BASS), or input level
knob 4 (TREBLE).
3 Press input level knobs 1 - 8 to select to which
input channel you would like to apply the EQ.
4 Turn the [SETUP] encoder to adjust the level of
EQ.
The parameter value changes with each click of the
encoder.
NOTE
If the set EQ value for [INPUT 7] and [INPUT 8] exceeds
+5dB, the enhancer function starts and harmonic
overtones are added.
5 Press the [SETUP] encoder to apply the setting.
The status is back to the channel select (Step 3).
2 3 1, 4, 5
-10dB:
-9 to -6dB:
-5dB:
-4 to -1dB:
0dB: (Default setting)
+1 to +4dB:
+5dB:
+6 to +9dB:
+10dB: