ortho remote for MMP1 Setup Guide Version 1.
Table of Contents 1. Introduction ........................................................................................................................ 3 2. Parameters that can be controlled from ortho remote ....................................................... 3 3. Devices and software to be used ....................................................................................... 4 4. Setup Procedures..................................................................................................
1. Introduction This guide describes how to configure ortho remote, the teenage engineering’s Bluetooth remote controller, for controlling MMP1, the Yamaha’s studio monitor management system via iPad. 【Connection diagram】 (BLE-MIDI) 【MMP1】 【switch】 【iPad (MMP1 Controller)】 【ortho remote】 2.
3. Devices and software to be used Here are the devices and software to be used in this example: 1. ortho remote 2. Mac with OSX 10.13.3 (10.10 or later is fine which is BLE-MIDI compatible) installed 3. SysEx Librarian v1.3.1 (MIDI device communication software) 4. Apple iPad with MMP1 Controller v1.1.0 installed (iOS10 or later) 4. Setup Procedures Below is the procedures for setting up ortho remote for controlling MMP1: 1. Update MMP1 Controller 2. Download and install SysEx Librarian 3.
Snoize: SysEx Librarian https://www.snoize.com/SysExLibrarian/ Click and download 【Snoize website】 Open the downloaded zip file and an application file will be created.
4-3. Download ortho remote configuration file Next, download the configuration file from the following Yamaha website: Yamaha MMP1 Download Page http://www.yamahaproaudio.com/global/en/products/processors/mmp1/downloads.jsp 【ortho remote configuration file】 4-4. Configure ortho remote In order to transfer data from Mac to ortho remote, the both devices need to be paired via Bluetooth. First, open Audio MIDI Setup from Utilities in the Application folder.
【Mac OSX Audio MIDI Setup】 Choose “Show MIDI Studio” from Window menu and MIDI Studio window will open.
Double click on the Bluetooth icon and Bluetooth Configuration window appears and Bluetooth devices become discoverable. 【Bluetooth Configuration】 Here, press and hold the pairing button of ortho remote on the back side of the unit for about 3 seconds, until the blue LED lights.
When ortho remote becomes discoverable, the name will appear in the Bluetooth Configuration window, click on “Connect” button to pair Mac and ortho remote. 【Bluetooth Configuration】 If both devices are successfully paired, the “ortho remote” device icon will appear in the MIDI Studio window.
Run the previously downloaded SysEx Librarian, click on the Destination and choose “Bluetooth”. 【SysEx Librarian Destination】 Next, load the configuration files on SysEx Librarian. Drag and drop the files onto SysEx Librarian, or choose “Add to Library...” from File menu and specify the files to be loaded.
Simply disregard the following message and click “ok” 【SysEx Librarian Confirmation Dialog】 【Configuration files loaded】 Choose either one of the 4 files (push_for_****.syx) by clicking the desired file. Each file contains not only a push command but also other commands for controlling the monitor level.
【Select configuration files】 Once the desired file is highlighted, click the Play button and the data transfer will take place. 【Sending message dialog】 The transfer will complete shortly, and the following message will appear.
4-5. Pair iPad and ortho remote Once ortho remote is configured, next is to pair iPad and ortho remote. Start MMP1 Controller and tap on the Preference tab.
【Select BLE MIDI Device】 Here, again, press and hold the pairing button of ortho remote on the back side of the unit for about 3 seconds, until the blue LED lights. You will see “ortho remote” appear in the screen.
Tap on “ortho remote” and then the “Connect” button to see the following request dialog. Tap on “Pair” and iPad and ortho remote will become paired. 【MMP1 Controller Bluetooth Pairing Request】 Now all the configuration is completed.
Caution: If you have problem with pairing ortho remote As you repeat connecting/disconnecting ortho remote and have too many “offline” devices registered on Mac, you won’t be able to add any more device to the list or have it paired with Mac. 【Too many “offline” devices are registered (Audio MIDI Setup - MIDI Studio)】 If that’s the case, remove those offline devices from the host device and try pairing again.
Next, open Bluetooth in System Preference in order to remove those offline devices. 【システム環境設定 - Bluetooth】 Click on the X button next to each device name, and then click “Remove” on the confirmation dialog.
Repeat this process until all the offline devices are removed. Same limitation goes with iPad and, if too many offline devices are registered, no more device can be added to iPad so you will remove those offline devices to pair the ortho remote.
If that’s the case, tap on the “i” button. 【“i” button】 And then tap on “Forget This Device in the next screen. 【Forget This Device button】 The confirmation dialog below will appear and tap on “OK” to remove the device. You may need to remove the devices one by one, until all the unnecessary offline devices are removed.
5.
1. Make the value changes relative (incremental) while rotating the knob (required) F0 00 20 76 00 02 02 00 F7 2. Control the monitor level when turning the knob (required) F0 00 20 76 02 00 01 10 F7 02 00 03 00 F7 03 0C F7 3. Mute when pressed (optional) F0 00 20 76 4. Dim the monitor level when pressed (optional) F0 00 20 76 00 02 5. Set the monitor level to the reference level when pressed (optional) F0 00 20 76 00 02 03 18 F7 03 24 F7 00 04 64 F7 6.
Config file 3.push_for_ref_level.syx F0 00 20 76 02 00 02 00 F7 F0 00 20 76 02 00 01 10 F7 F0 00 20 76 02 00 03 18 F7 F0 00 20 76 02 00 04 64 F7 Config file4. push_for_all_mute.