NumberOfTimes Determines the number of times the data creation is to be repeated.
For example, if data is created in the range M001:1:000 – M003:1:000 and this parameter is set to 03, the same
data will be created at M003:1:000 – M005:1:000 and M005:1:000 – M007:1:000. This Job lets you insert
continuous volume or filter cutoff variations to create tremolo or wah effects.
Settings: 01 – 99
06: Thin Out
This Job thins out the specified type of continuous data in the specified range—allowing you to free up memory
space for other data or further recording.
TR (Track)
001 : 1 : 000 – 999 : 4 : 479
Determines the track (01 – 16, TMP, all) and range of measures/beats/clocks over which the Job is applied.
EventType Determines the event type to be thinned.
Settings: PB (Pitch Bend), CC (Control Change)*, CAT (Channel Aftertouch), PAT (Polyphonic Aftertouch), TMP (Tempo)
* You can also specify the CC No. (Control Change number).
n The Thin Out Job will not work on continuous data that has a clock interval of greater than 60 clocks per event.
07: Modify Control Data
This Job lets you change the values of a specified type of control change data—pitch bend, control change,
aftertouch, etc.—in the specified range. Data changes are calculated as follows:
Modified value = (original value x Rate) + Offset.
The modified value cannot exceed the minimum/maximum limits of the parameter. Any result lower than the
minimum is set to the minimum; any result higher than the maximum is set to the maximum.
TR (Track)
001 : 1 : 000 – 999 : 4 : 479
Determines the track (01 – 16, TMP, all) and range of measures/beats/clocks over which the Job is applied.
EventType Determines the event type to be modified.
Settings: PB (Pitch Bend), CC (Control Change)*, CAT (Channel Aftertouch), PAT (Polyphonic Aftertouch), TMP (Tempo)
* You can also specify the CC No. (Control Change number).
SetAll Sets all target events to the same fixed value. When set to “off,” the Set All parameter has no effect. When set
to a value other than “off,” the Rate and Offset parameters are unavailable and appear as “***” on the display.
Settings: off, 000 –127 (-8192 – +8191 for pitch bend, 0.1 – 300.0 for tempo)
Rate Determines the percentage by which the target events will be shifted from their original values. When the Set
All parameter (above) is set to something other than “off,” this parameter appears as “***” and cannot be
changed.
Settings: 000% – 200%, ***
Offset Adds a fixed value to the Rate-adjusted event values. When the Set All parameter (above) is set to something
other than “off,” this parameter appears as “***” and cannot be changed.
Settings: -127 – 127 (-8192 – +8191 for pitch bend, -275 – +275 for tempo), ***
08: Beat Stretch
This Job performs time-expansion or compression over the selected range. Keep in mind that this operation
affects all event timing, note step times, and note gate times.
TR (Track)
001 : 1 : 000 – 999 : 4 : 479
Determines the track (01 – 16, all) and range of measures/beats/clocks over which the Job is applied.
Rate Determines the amount of time expansion or compression as a percentage. Settings higher than 100%
produce expansion, and settings below 100% produce compression.
Settings: 025%–400%
[F4] MEAS (Measure Job)
01: Create Measure
This Job creates empty measures at the specified location in all tracks.
Meter of measures to be inserted Determines the meter or time signature of the measures to be created. You may find it convenient to use this
parameter when you need to create a Song that incorporates meter changes.
Settings: 1/16 – 16/16, 1/8 – 16/8, 1/4 – 8/4
Insertion point
(Measure number)
Determines the insert point (measure number) at which the newly created blank measures will be inserted.
Settings: 001 – 999
Number of measures to be
inserted
Determines the number of empty measures to be created and inserted.
Settings: 01 – 99
n When empty measures are inserted, measure and meter data following the insert point are moved forward accordingly.
n If the insert point is set after the last measure containing data, only the meter data at that point is set without actually inserting the measures.
001 – 004 005 013
001 – 004 005 016
024012––
Meter (time signature) of
measures to be inserted
Number of measures
to be inserted
Insertion point (measure number)
8 measures inserted at measure 5
The inserted 8 measures
Source data