User Manual

VXL1-16P Remote Control Protocol Specications Version 1.0.0 rev1
23
5. Meter Value
5.1. Level Meter, Hold Meter, GR Meter
5.1.1.
Value Data Value Data Value Data Value Data
00 -126dBFs or less 20 -94dBFs 40 -62dBFs 60 -30dBFs
01 -125dBFs 21 -93dBFs 41 -61dBFs 61 -29dBFs
02 -124dBFs 22 -92dBFs 42 -60dBFs 62 -28dBFs
03 -123dBFs 23 -91dBFs 43 -59dBFs 63 -27dBFs
04 -122dBFs 24 -90dBFs 44 -58dBFs 66 -26dBFs
05 -121dBFs 25 -89dBFs 45 -57dBFs 65 -25dBFs
06 -120dBFs 26 -88dBFs 46 -56dBFs 66 -24dBFs
07 -119dBFs 27 -87dBFs 47 -55dBFs 67 -23dBFs
08 -118dBFs 28 -86dBFs 48 -54dBFs 68 -22dBFs
09 -117dBFs 29 -85dBFs 49 -53dBFs 69 -21dBFs
0A -116dBFs 2A -84dBFs 4A -52dBFs 6A -20dBFs
0B -115dBFs 2B -83dBFs 4B -51dBFs 6B -19dBFs
0C -114dBFs 2C -82dBFs 4C -50dBFs 6C -18dBFs
0D -113dBFs 2D -81dBFs 4D -49dBFs 6D -17dBFs
0E -112dBFs 2E -80dBFs 4E -48dBFs 6E -16dBFs
0F -111dBFs 2F -79dBFs 4F -47dBFs 6F -15dBFs
10 -110dBFs 30 -78dBFs 50 -46dBFs 70 -14dBFs
11 -109dBFs 31 -77dBFs 51 -45dBFs 71 -13dBFs
12 -108dBFs 32 -76dBFs 52 -44dBFs 72 -12dBFs
13 -107dBFs 33 -75dBFs 55 -43dBFs 77 -11dBFs
14 -106dBFs 34 -74dBFs 54 -42dBFs 74 -10dBFs
15 -105dBFs 35 -73dBFs 55 -41dBFs 77 -9dBFs
16 -104dBFs 36 -72dBFs 56 -40dBFs 76 -8dBFs
17 -103dBFs 37 -71dBFs 57 -39dBFs 77 -7dBFs
18 -102dBFs 38 -70dBFs 58 -38dBFs 78 -6dBFs
19 -101dBFs 39 -69dBFs 59 -37dBFs 79 -5dBFs
1A -100dBFs 3A -68dBFs 5A -36dBFs 7A -4dBFs
1B -99dBFs 3B -67dBFs 5B -35dBFs 7B -3dBFs
1C -98dBFs 3C -66dBFs 5C -34dBFs 7C -2dBFs
1D -97dBFs 3D -65dBFs 5D -33dBFs 7D -1dBFs
1E -96dBFs 3E -64dBFs 5E -32dBFs 7E 0dBFs
1F -95dBFs 3F -63dBFs 5F -31dBFs 7F OVER
NOTE: A device may not be able to send all the values depending on how precise the device processes values internally.