User Manual

Part Parameters
34
C: Time
D: Level (volume)
E: Hold Time
F: Attack Time
G: Decay 1 Time
H: Decay 2 Time
I: Release Time
J: Attack Level
K: Decay 1 Level
L: Decay 2 Level
M: Release (Hold) Level
AEG Attack Time Determines how quickly the sound reaches its maximum level after the key
is pressed.
AEG Decay 1 Time Determines how fast the envelope falls from the Attack Level to the
Decay 1 Level.
AEG Decay 2 Time Determines how fast the envelope falls from the Decay 1 Level to the
Decay 2 Level (sustain level).
AEG Release Time Determines how quickly the sound decays to silence after the key is
released.
AEG Initial Level Determines the initial level at the moment the key is pressed.
AEG Attack Level Determines the maximum level which the envelope reaches after a key is
pressed.
AEG Decay 1 Level Determines the level which the envelope reaches from the Attack Level
after the Decay 1 Time elapses.
AEG Decay 2 Level Determines the level which will be maintained while a note is held.
AEG Release (Hold)
Level (For Normal Parts
(FM-X))
Determines the final level reached after the note is released.
AEG Hold Time Determines the time between the moment you press a key on the
keyboard and the moment the level reaches the specified hold level.
AEG Time Key Follow
Sensitivity
Determines the degree to which the notes (specifically, their position or
Octave Range) affect the Amplitude EG times.
Positive values: High notes result in a fast Amplitude EG transition
speed while low notes result in a slow speed.
Negative values (for Normal Part (AWM2)): High notes result in a
slow Amplitude EG transition speed while low notes result in a fast
speed.
0: The Amplitude EG transition speed does not change, regardless of
the played note.