User Manual

MONTAGE Data List
213
MIDI Data Table
TOTAL SIZE = 117 75 (HEX)
p = Part number
0 – F
TOTAL SIZE = 27 1B (HEX)
p = Part number
0 – F
69 1 00 – 7F Controller Set 12
Curve Parameter 2
0 – 127 00 Fixed to “0”
except when
Bank is set to
Preset
6A 1 00 – 01 Controller Set 12
Curve Polarity
Uni, Bi 00
6B 1 00 – 7F Controller Set 12
Curve Ratio
-64 – +63 60
6C 1 00 – 27 Controller Set 13
Source
0 – 39 (Refer to Controller
Box Source of Control List)
01
6D 2 00 – 00
00 – 74
Controller Set 13
Destination
1st bit6-0 bit13-7
2nd bit6-0 bit6-0
0 – 115 (Refer to Controller
Box Destination of Control
List)
00 00
6F 1 00 – 09 Controller Set 13
Curve Bank
0 = Preset, 1 = User, 2 =
Library1...9 = Library8
00
70 1 00 – 1F Controller Set 13
Curve Type
0 – 31 (0 – 17 when Bank
is set to Preset)
00
71 1 00 – 7F Controller Set 13
Curve Parameter 1
0 – 127 05 Fixed to “0”
except when
Bank is set to
Preset
72 1 00 – 7F Controller Set 13
Curve Parameter 2
0 – 127 00 Fixed to “0”
except when
Bank is set to
Preset
73 1 00 – 01 Controller Set 13
Curve Polarity
Uni, Bi 00
74 1 00 – 7F Controller Set 13
Curve Ratio
-64 – +63 60
Address Size
Range
(HEX)
Parameter Name Description
Default
(HEX)
Notes
38 1p 00 1 00 – 27 Controller Set 14
Source
0 – 39 (Refer to Controller
Box Source of Control List)
01
01 2 00 – 00
00 – 74
Controller Set 14
Destination
1st bit6-0 bit13-7
2nd bit6-0 bit6-0
0 – 115 (Refer to Controller
Box Destination of Control
List)
00 00
03 1 00 – 09 Controller Set 14
Curve Bank
0 = Preset, 1 = User, 2 =
Library1...9 = Library8
00
04 1 00 – 1F Controller Set 14
Curve Type
0 – 31 (0 – 17 when Bank
is set to Preset)
00
05 1 00 – 7F Controller Set 14
Curve Parameter 1
0 – 127 05 Fixed to “0”
except when
Bank is set to
Preset
06 1 00 – 7F Controller Set 14
Curve Parameter 2
0 – 127 00 Fixed to “0”
except when
Bank is set to
Preset
07 1 00 – 01 Controller Set 14
Curve Polarity
Uni, Bi 00
08 1 00 – 7F Controller Set 14
Curve Ratio
-64 – +63 60
09 1 00 – 27 Controller Set 15
Source
0 – 39 (Refer to Controller
Box Source of Control List)
01
0A 2 00 – 00
00 – 74
Controller Set 15
Destination
1st bit6-0 bit13-7
2nd bit6-0 bit6-0
0 – 115 (Refer to Controller
Box Destination of Control
List)
00 00
0C 1 00 – 09 Controller Set 15
Curve Bank
0 = Preset, 1 = User, 2 =
Library1...9 = Library8
00
0D 1 00 – 1F Controller Set 15
Curve Type
0 – 31 (0 – 17 when Bank
is set to Preset)
00
0E 1 00 – 7F Controller Set 15
Curve Parameter 1
0 – 127 05 Fixed to “0”
except when
Bank is set to
Preset
0F 1 00 – 7F Controller Set 15
Curve Parameter 2
0 – 127 00 Fixed to “0”
except when
Bank is set to
Preset
10 1 00 – 01 Controller Set 15
Curve Polarity
Uni, Bi 00
11 1 00 – 7F Controller Set 15
Curve Ratio
-64 – +63 60
12 1 00 – 27 Controller Set 16
Source
0 – 39 (Refer to Controller
Box Source of Control List)
01
13 2 00 – 00
00 – 74
Controller Set 16
Destination
1st bit6-0 bit13-7
2nd bit6-0 bit6-0
0 – 115 (Refer to Controller
Box Destination of Control
List)
00 00
15 1 00 – 09 Controller Set 16
Curve Bank
0 = Preset, 1 = User, 2 =
Libr
ar
y1...9 = Library8
00
16 1 00 – 1F Controller Set 16
Curve Type
0 – 31 (0 – 17 when Bank
is set to Preset)
00
17 1 00 – 7F Controller Set 16
Curve Parameter 1
0 – 127 05 Fixed to “0”
except when
Bank is set to
Preset
Address Size
Data
Range
(HEX)
Parameter Name Description
Default
(HEX)
Notes
18 1 00 – 7F Controller Set 16
Curve Parameter 2
0 – 127 00 Fixed to “0”
except when
Bank is set to
Preset
19 1 00 – 01 Controller Set 16
Curve Polarity
Uni, Bi 00
1A 1 00 – 7F Controller Set 16
Curve Ratio
-64 – +63 60
Address Size
Range
(HEX)
Parameter Name Description
Default
(HEX)
Notes