User Manual
Table Of Contents
- Notice regarding data copyright
- Notice regarding the content of this user guide
- Contents
- Chapter 1. An overview of MTX-MRX Editor
- An audio system control network
- Terms used in this user guide
- Data handled by MTX-MRX Editor
- Connection requirements for an MTX/MRX system
- MTX/MRX system configuration examples
- What are YDIF connections? (Cascade mode and Distribution mode)
- What are Dante connections? (Daisy-chain connection and Star connection)
- Patching
- Workflow
- About the screens
- Moving between screens
- Chapter 2. Menu bar and tool buttons
- Chapter 3. Project screen
- Chapter 4. System screen
- Chapter 5. Online and Synchronization
- Chapter 6. Presets
- Chapter 7. Dialog boxes/Software applications
- “Startup” dialog box
- “Network Setup” dialog box
- “Device Information” dialog box
- “Match Device by IP Address” dialog box
- “MTX Configuration” dialog box
- “Dante Information” dialog box
- “Word Clock” dialog box
- “Clock” dialog box
- “Daylight Saving Time” dialog box
- “Scheduler” dialog box
- “Remote Control” dialog box
- “External Events” dialog box
- “Digital Control Panel” dialog box
- “Wireless DCP” dialog box
- “MCP1” dialog box
- “PIN Setup” dialog box
- “Label” dialog box
- “Re-size Image” dialog box
- “PGM1/PGX1” dialog box
- “PGM1 Label Creator” application
- “GPI” dialog box
- “GPI Calibration” dialog box
- “Security Settings” dialog box
- “Project Information” dialog box
- “Configuration Diagram” dialog box
- “Get Log” dialog box
- “Sampling Rate Converter” dialog box
- “Input Source/Redundant” dialog box
- Appendix
“Device Configuration Wizard” dialog box Chapter 3. Project screen
MTX-MRX Editor User Guide
39
3. Specify the type and number of devices that will be assigned to the
MTX/MRX system.
Determine the number of devices that will be connected via cable, other than digital
control panels.
If you selected [Edit Configuration] in the first screen of the wizard, the currently-
assigned number of devices is shown. In this case, it is not possible to change the
number of units to less than this number or to greater than Connection
requirements for an MTX/MRX system.
Devices whose number of units is set to 0 will be dimmed and unavailable.
On the Tio1608-D, the UNIT ID range is narrower. When using the Tio1608-D, avoid
using UNIT ID settings 01–0C for other devices in the next screen.
• [Number] box
Specifies the number of devices.
•[Cancel] button
Cancels the operation and exits the wizard.
• [< Back] button
This button will be dimmed and unavailable.
• [Next >] button
Applies the changes and proceeds to the next screen.
• [Finish] button
This button will be dimmed and unavailable.
NOTE