User Manual

Table Of Contents
Menu bar
Yamaha LAN Monitor for Win User Guide
14
4 Update interval of device information
Set the device monitoring time interval in seconds.
Setting range: 10 – 86400 sec
Default: 1800 sec
This will detect devices connected to a slave every time the set amount of time elapses.
5 Keepalive
This pings slaves and devices with an IP address to confirm their existence. This is used to set the ping
interval, the wait time for reply, and the number of failed attempts before a connection is assumed to be down.
•Interval time:
Set the ping interval in seconds.
Setting range: 1 – 1800 sec
Default: 10 sec
Wait time for reply:
Set the wait time for reply to pings in seconds.
Setting range: 1 – 60 sec
Default: 1 sec
Number of failure for detecting down:
Set the number of failures before a connection is detected as being down.
Setting range: 1 – 100 times
Default: 3 times
6 Power supply interruption time
Suspends the power supply when a disrupted or inactive connection is detected. Set the power supply
interruption time in seconds in case of interruption.
Setting range: 1 – 60 sec
Default: 5 sec
7 Preview size of the Whole map
Select the size of the preview image of the “Whole map” generated for print preview and printing.
If printing or previewing the “Whole map” has failed, the failure may be avoided by setting the preview size to A6.
8 Snapshot function
“Treat equipment as comparison for snapshots” check box:
Clear this check box to exclude devices as targets for comparisons.
Default: Selected
9 [OK] button
Applies the configured settings.
NOTE
The [OK] button is only available when acceptable input values have been input.
Click the [OK] button to reset the monitoring timer and begin counting from 0 seconds again.
) [Cancel] button
Closes the dialog box without applying setting changes.