“EXi8” screen
Here you can view and edit the parameters of the EXi8 units in the MTX/MRX system. When you
right-click on the display area of a desired EXi8, a context menu appears, allowing you to copy and
paste settings between devices.
1 [EDIT] button
This enables the EXi8 output routing select buttons.
The [EDIT] button is available only in the offline state.
2 EXi8 identification area
Shows the UNIT ID, model type, and model name of the corresponding EXi8 unit.
3 Channel index
Indicates the channel number of the EXi8.
4 [+48V] button
Turns the HA phantom power (+48V) on/off.
Notice
Be sure to leave this button off if you do not need phantom power.
When turning phantom power on, you must observe the precautions below in order to
prevent noise and possible damage to the unit and to external devices.
Leave this button off if a device that does not support phantom power is connected to the
[INPUT] connector.
Do not connect/disconnect a cable to/from the [INPUT] connector while this button is
on.
Lower the output level to the minimum before turning phantom power on/off.
There is no master switch. To avoid malfunctions, be sure to set this appropriately for the
equipment that is connected.
57
1
3
6
9
0
2
4
8
NOTE