User Manual

Table Of Contents
If [FUNCTION] is [MRX Parameter]
MRX Designer User Guide
134
If the [Control Type] is [Knob Assign] (DCP1V4S only)
The switch changes what will be controlled by the knob.
Choose this if you want the knob to have more than one function.
[Parameter Range]
Use [Upper Limit] and [Lower Limit] to specify the range in which the level can be varied.
If [Mute Enable] is on, the Mute state (–∞ dB) will be enabled if the level is lowered
below the value specified by [Lower Limit].
If the nominal value specified by the following [Nominal Value] is higher than the
[Upper Limit], the [Upper Limit] will rise in tandem with the [Nominal Value].
Conversely, if the nominal value goes below the [Lower Limit], the [Lower Limit] will
fall in tandem with the [Nominal Value].
By using [Parameter Range] you can limit the range in which the user can control
the volume. For example you can use this to specify the maximum volume of
background music, or use a controller to make fine volume adjustments in a narrow
range of –6 dB to +6 dB.
[Nominal] check box
Here you can make settings for the Nominal function.
By specifying the nominal value, you can assign a specific LED position as the
normal volume setting. For example by specifying the center LED as the volume
setting for normal use and setting the maximum value to the maximum volume that
is allowable for the system, you can prevent damage to the system that might occur
if the volume of the background music were raised during a noisy time.
If the check box is selected, the Nominal function will be on.
[Nominal Value] specifies the nominal value.
[Nominal LED Position] specifies the LED position that will light when the level
reaches the nominal value.
If the check box is cleared (Nominal function off), both parameters will be grayed-
out and unavailable.
NOTE