If [FUNCTION] is [MRX Source Select] (DCP/Wireless DCP)
MRX Designer User Guide
137
We will explain the settings for the switch and the knob/slider in this example.
Switch settings
Select the following parameter type to be operated by the switch, and then make various settings.
•Source Select
[PARAMETER1]/[PARAMETER2]
[PARAMETER1] shows the component that is specified in the “Source Select” tab.
[PARAMETER2] specifies the source that will be turned on. ON can be specified
only for one source.
Knob/slider settings
[PARAMETER1]/[PARAMETER2]
[PARAMETER1] shows the component that is specified in the “Source Select” tab.
If the above switch is used to change the source of the “Source Selector” component,
the level-type parameter specified below is assigned to the knob/slider.
The following parameters can be specified for each source ([each one of [PARAMETER2]).
[Select Parameter:]
Specify the level-type parameter that will be linked with the selected source. The
[Clear] button clears the parameter.
[Parameter Range]
Use [Upper Limit] and [Lower Limit] to specify the range in which the level can be varied.
If [Mute Enable] is on, the Mute state (–∞ dB) will be enabled if the level is lowered
below the value specified by [Lower Limit].
If the nominal value specified by the following [Nominal Value] is higher than the
[Upper Limit], the [Upper Limit] will rise in tandem with the [Nominal Value].
Conversely, if the nominal value goes below the [Lower Limit], the [Lower Limit] will
fall in tandem with the [Nominal Value].
By using [Parameter Range] you can limit the range in which the user can control
the volume. For example you can use this to specify the maximum volume of
background music, or use a controller to make fine volume adjustments in a narrow
range of –6 dB to +6 dB.
[Nominal] check box (DCP only)
Here you can make settings for the Nominal function.
By specifying the nominal value, you can assign a specific LED position as the
normal volume setting. For example by specifying the center LED as the volume
setting for normal use and setting the maximum value to the maximum volume that
is allowable for the system, you can prevent damage to the system that might occur
if the volume of the background music were raised during a noisy time.
If the check box is selected, the Nominal function will be on.
[Nominal Value] specifies the nominal value.
[Nominal LED Position] specifies the LED position that will light when the level
reaches the nominal value.
If the check box is cleared (Nominal function off), both parameters will be grayed-
out and unavailable.
[Knob] (DCP only)
Here you can make settings for the DCP’s knobs.
[Sensitivity] specifies the sensitivity at which the parameter will change when the
knob is rotated.
If [Acceleration] is on, the parameter will change faster if the knob is rotated more
rapidly. If [Fast] is selected as the [Sensitivity], the [Acceleration] setting is dimmed
and unavailable.
NOTE