User Manual

Table Of Contents
“Parameter Link Group” area
MRX Designer User Guide
37
“Parameter Link Group” area
You can create a parameter link group that links multiple parameters such as Level or ON/OFF. The
parameters of multiple MRX units within the MTX/MRX system can be registered in a single
parameter link group. A single parameter can also be registered in more than one parameter link group.
A created parameter link group can be used with a snapshot, scheduler, GPI, DCP, Wireless DCP, or
Remote Control Setup List.
Level-type parameters and ON/OFF-type parameters cannot coexist in a single parameter link group.
For each MTX/MRX system, there can be up to 64 parameter link groups.
Parameters can be registered in a parameter link group in the following ways.
If any parameter link group in the “Parameter Link Group” area is selected, pressing an
alphabetical key will select the parameter link group of the matching initial letter.
Registration source Registration method
Component editor /
Parameter setting
window
While holding down <Ctrl>, drag and drop a parameter onto a parameter link
group name.
Right-click a parameter, and use [Add to Parameter Link Group] to select the
parameter link group in which it will be registered.
“Parameters” area
*1
*1. You can also use <Shift> or <Ctrl> to simultaneously register multiple parameters in a parameter link group.
Drag and drop a parameter onto a parameter link group name.
Right-click a parameter, and use [Add to Parameter Link Group] to select the
parameter link group in which it will be registered.
1 [New] button
Creates a new parameter link group.
2 [Delete] button
Deletes the selected parameter link group or
parameter.
3 [Open] button
Displays the Link Master editor for the selected
parameter link group.
4 [+]/[–] buttons
Completely expands or completely minimizes
the parameter link group display.
NOTE
4
1
2
3