“Paging Ducker” component editor
MRX Designer User Guide
71
3 [RANGE] knob/indicator
The knob sets the audio signal level of the program source when the TRIGGER [ON]
button is on. The indicator is lit when the signal decreases to the level specified by the
knob. If you attach an LED to GPI and register the [RANGE] indicator to GPI, you’ll be
able to check whether the paging mic is active.
4 [ATTACK] knob
Specifies the time over which the audio signal level of the program source decreases to
the level specified by the [RANGE] knob, starting when the TRIGGER [ON] button
turns on.
5 [HOLD] knob
Specifies the time after which the audio signal level of the program source starts
returning to the original level after the TRIGGER [ON] button turns off.
6 [RELEASE] knob
Specifies the time over which the audio signal level of the program source returns to the
original level after the time specified by the [HOLD] knob.
7 [OUTPUT] meter
Shows the output signal level.