16 SWR2100P-10G/SWR2100P-5G Owner’s Manual
Setting the CONFIGURATION switches
You can enable or disable functions for
this unit by setting the CONFIGURATION
switches.
In order to operate the switches, please
use something round, such as the tip of a
ballpoint pen or small screwdriver. This
unit reads the switch status at startup and
enables or disables functions as
indicated. If the switch status is changed
after startup, the new switch status will be
in effect at the next startup.
The functions which can be set via the CONFIGURATION switches are as follows.
* This is the factory default setting.
L2MS (Layer 2 Management Service) function
This function manages Yamaha network devices, including this unit, at the layer 2 level.
You can control the unit from a Yamaha LAN Monitor that features the L2MS controller
function.
Low power consumption mode
The lower power consumption mode of this unit is compatible with the following methods
of IEEE802.3az Energy Efficient Ethernet (called “EEE” in this manual).
10BASE-Te
100BASE-TX/1000BASE-T (LPI)
NOTE
Do not use the EEE function (*) on the network switch within the Dante network.
Between switches that feature the EEE function, the setting for power consumption is
automatically adjusted. However, some switches might not respond correctly to this
adjustment. Therefore, the EEE function on some switches might be enabled accidentally
within the Dante network, which might cause clock sync performance to deteriorate and result
in audio that breaks up.
* EEE (Energy Efficient Ethernet) function is used to reduce power consumption of Ethernet devices when
network traffic is low. This technology is also called “Green Ethernet” or “IEE802.3az”.
CONFIGURATION
switches
No. Setting function OFF ON
1 L2MS (Layer 2 Management Service) function Disabled Enabled*
2 Flow control Disabled Enabled*
3 Auto MDI/MDI-X Disabled Enabled*
4 Loop detection function Disabled* Enabled
5 Low power consumption mode Disabled* Enabled