User Manual

Input channels Chapter 4. System screen
MTX-MRX Editor User Guide
62
Parameter edit screen (for the EXi8)
A
C
B
D
E
F
G
H
I
K
J
A Meter
Shows the input signal level.
B [+48V] button
Turns the HA phantom power (+48V) on/off.
Notice
Be sure to leave this button off if you do not need phantom power.
Follow the important precautions below, in order to prevent noise
and possible damage to external devices as well as the unit when
you operate this switch.
Be sure to leave this button off when you connect a device that
does not support phantom power to [INPUT] connector.
Do not connect/disconnect a cable to/from [INPUT] connector
while this button is on.
Down the output level to the minimum before operating this
button.
There is no master switch. To avoid malfunctions, be sure to set
this appropriately for the equipment that is connected.
C [GAIN] knob
Adjusts the analog gain of the HA (head amp)
D HA analog gain
Shows the HA analog gain setting.
E [HPF] button
Switches the HPF (High Pass Filter) on/off.
F [Freq] knob
Specifies the cutoff frequency of the HPF.
G Cutoff frequency
Indicates the cutoff frequency of the HPF.
H [Ø] button
Switches the phase of the input signal.
I [ON] button
Switches the input channel on/off.
J Channel name
Indicates the channel name of the EXi8. You can double-click
this and edit it.
K Channel index
Indicates the number of the devices input connector. If you
place the cursor here, a popup will show the UNIT ID and the
name of the external device.
NOTE