User Manual

15MCP1 Installation Manual
Alert list
The following table lists the alerts generated by the MCP1, their meaning, and the appropriate
action to take.
When a Fault type alert occurs, it will immediately be displayed. Other alert types can be
checked by touching [Alert] in the Settings page. A single occurrence is shown when the situa-
tion occurs. A continuous occurrence is shown when the situation occurs and when it ends.
If the problem cannot be solved, contact your Yamaha dealer.
Number Content Action Type
Single /
Continuing
Device abnormality
001
The unit did not start up nor-
mally.
Turn off the power supply of the
PSE, wait at least six seconds,
and then turn on the power. If
this does not solve the problem,
initialize the MCP1.
Fault Continuing
003
Failed writing to internal flash
ROM.
Fault Continuing
005 MAC address was lost. Fault Continuing
017
Settings saved in internal
memory were lost.
Perform synchronization again
using MTX-MRX Editor.
Fault Continuing
040 The IP address conflicts.
Make settings so that the IP
address does not conflict.
Error Continuing
041
The IP address was not estab-
lished within 60 seconds after
startup.
If the IP Setting is set to “PC,
use MTX-MRX Editor or the
DHCP server to specify the IP
address.
Warning Continuing
042
The devices making up the
MTX/MRX system were not
found on the network.
Power-on all devices making up
the system, and make sure that
they are correctly connected to
the network.
Error Continuing
043
Too m a ny d evices are con-
nected to the network.
Reduce the number of devices
connected to the network.
Error Single
051
A device with the same UNIT
ID was found among the
devices connected to the same
network.
Make settings so that the UNIT
ID does not conflict.
Error Continuing
060 Failed to recall a preset. Initialize the MCP1. Error Continuing
064
The preset could not be
recalled.
The Preset selected for recall
cannot be recalled as no data
has been stored to it, or another
device may have been added
after presets were stored.
Please synchronize and check
all presets using MTX-MRX
Editor, and store again.
Warning Continuing