User Manual

Table Of Contents
MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V3.3.1 rev13
85
7. Parameter List
Model Access ID
Category Parameter Name MIN MAX unit Remarks
MTX3
MTX5-D
MemNo
(Memory
Number)
UniqueId
ElmNo
(Element
Number)
Xpos
(X Position)
Ypos
(Y Position)
PrmNo
(Parameter
Number)
IndexNo
(Index
Number)
o 512 40002 0 0-7
(1-8ch)
0 0 0
INPUT
CHANNEL
INPUT
CHANNEL
CH
1-8(16)
GATE Gate
8(16)
Channel
Dyn
Threshold
-72 0 dB
o 40000
o
40001 0-7
(9-16ch)
o 40002 0 0-7
(1-8ch)
0 1 0 Range -70 0 dB
o 40000
o
40001 0-7
(9-16ch)
o 40002 0 0-7
(1-8ch)
0 2 0 Attack 0 120 ms
o 40000
o
40001 0-7
(9-16ch)
o 40002 0 0-7
(1-8ch)
0 3 0 Decay 3.2m
42.600
s * See "6.2.2.2.
GATE" in "6.
Parameter
Values"
o 40000
o
40001 0-7
(9-16ch)
o 40002 0 0-7
(1-8ch)
0 4 0 Hold 0.02m 1.96 s * See "6.2.2.2.
GATE" in "6.
Parameter
Values"
o 40000
o
40001 0-7
(9-16ch)
o 40002 1 0-7
(1-8ch)
0 0 0 ON On OFF ON - 0:OFF
1:ON
o 40000
o
40001 0-7
(9-16ch)
o 40000 0 0-7
(1-8ch)
0 0 0
COMPRESSOR
Compressor
8(16)
Channel
Dyn
Threshold
-54 0 dB
o 40002
o
40003 0-7
(9-16ch)
o 40000 0 0-7
(1-8ch)
0 1 0 Ratio 1.0:1 ∞:1 -
* See "6.2.2.3.
COMPRESSOR"
in "6. Parameter
Values"
o 40002
o
40003 0-7
(9-16ch)
o 40000 0 0-7
(1-8ch)
0 2 0 Knee HARD 5 -
* See "6.2.2.3.
COMPRESSOR"
in "6. Parameter
Values"
o 40002
o
40003 0-7
(9-16ch)
o 40000 0 0-7
(1-8ch)
0 3 0 Attack 0 120 ms
o 40002
o
40003 0-7
(9-16ch)
o 40000 0 0-7
(1-8ch)
0 4 0
Release
3.2m
42.600
s
* See "6.2.2.2.
GATE" / Decay
in "6. Parameter
Values"
o 40002
o
40003 0-7
(9-16ch)
o 40000
0 0-7
(1-8ch)
0 5 0 Gain 0.0 18.0 dB dB x 10
ex. 5.2dB x 10
= 52
o 40002
o
40003 0-7
(9-16ch)
o 40000 1 0-7
(1-8ch)
0 0 0 ON On OFF ON - 0:OFF
1:ON
o 40002
o
40003 0-7
(9-16ch)
o
40005 0 0-3
(1-4ch)
0 0 0 FBS
Feedback
Suppressor
4(8)
Channel
Dynamic
Auto
Detect
OFF ON - 0:OFF
1:ON
o
40004 0-7
(1-8ch)
o
40005 0 0-3
(1-4ch)
0 1 0 Clear OFF ON -
Write 1 to start
the clear process.
When the process
nishes, the value
automatically
returns to 0.
o
40004 0-7
(1-8ch)
o
40005 1 0-3
(1-4ch)
0-6
(Freq1-7)
0 0
DynFilter
Frequency
20.0 20.0k Hz read-only
parameter
o
40004 0-7
(1-8ch)
o
40005 2 0-3
(1-4ch)
0 0 0 Fixed On OFF ON - 0:OFF
1:ON
o
40004 0-7
(1-8ch)
o
40005 2 0-3
(1-4ch)
0 1
0 Detect OFF ON - 0:OFF
1:ON
o
40004 0-7
(1-8ch)
o
40005 2 0-3
(1-4ch)
0 2 0 Clear OFF ON -
Write 1 to start
the clear process.
When the process
nishes, the value
automatically
returns to 0.
o
40004 0-7
(1-8ch)