“GPI Calibration” dialog box
Here you can calibrate the input voltage detection range for the [GPI] connector of the MTX unit.
(Available only when online.) These settings adjust the detection range in order to stabilize the
input voltage of the [GPI] connector.
[Device:] box
Selects an MTX unit within the MTX system.
From the left, this shows the “UNIT ID,Type (model name of the device),” and
“Device Name (name of the device).
Channel select check boxes
Calibration will be applied to the channels whose boxes are selected.
[All Ports] check box
Selects the check boxes of all channels.
Calibration data
The input voltage is shown in real time as a graph.
[Reset] button
Calibration will be reset for the channels whose boxes are selected.
[Max] button
Sets the current input voltage of the selected channels to the maximum value.
The maximum value you set is shown by a red bar.
[Min] button
Sets the current input voltage of the selected channels to the minimum value.
The minimum value you set is shown by a blue bar.