User Guide

31
MIDI Data Format
11110000 F0 Exclusive status
01000011 43 YAMAHA ID
0001nnnn 1n Device Number
01001100 4C XG Model ID
00000010 02 Address High
00000001 01 Address Mid
00001011 0B Address Low
01000000 40 Data (MSB)
00000000 00 Data (LSB) Æ fixed at
00.
11110111 F7 End of Exclusive
When this data is received, the MU10 will change
the effect Dry/Wet balance of Stage 1 to 50%
each.
Be sure to allow enough time for the procedure to
take place by inserting an empty measure at the
top of the song for every channel.
2.1.4.3 Multi Effect1 Data parameter change
See Tables 1-1 and 1-3.
2.1.4.4 Multi Part Data parameter change
See Tables 1-1 and 1-4.
2.1.4.5 A/D Part Data parameter change
See Tables 1-1 and 1-5.
2.1.4.6 Drums Setup Data parameter change
See Tables 1-1 and 1-6.
If a Drum Setup Reset parameter change message
(Table 1-2) is received, the Drum Setup parameter
values will be initialized. Selecting a Drum Set will
cause the Drum Setup parameter values to be
initialized.
2.1.5 MU10 Native Parameter Change
11110000 F0 Exclusive status
01000011 43 YAMAHA ID
0001nnnn 1n Device Number
01001001 49 Model ID
0aaaaaaa aa Address High
0aaaaaaa aa Address Mid
0aaaaaaa aa Address Low
0ddddddd dd Data
||
11110111 F7 End of Exclusive
2.1.5.1 MU10 System Data parameter change
See Tables 2-1 and 2-2.
2.1.6 Other parameter changes
2.1.6.1 Master Tuning
11110000 F0 Exclusive status
01000011 43 YAMAHA ID
0001nnnn 1n Device Number
00100111 27 Model ID
00110000 30 Sub ID2
00000000 00
00000000 00
0mmmmmmm mm Master Tune MSB
01111111 11 Master Tune LSB
Occccccc cc irrelevant
11110111 F7 End of Exclusive
This message simultaneously changes the pitch of
all channels.
2.2 Bulk Dump
The MU10 receives the following bulk dump data.
[ XG NATIVE ]
1) XG System Data
2) Multi Effect1 Data
3) Multi Part Data
4) A/D Part Data
5) Drums Setup Data
2.1.4.1 XG System On
11110000 F0 Exclusive status
01000011 43 YAMAHA ID
0001nnnn 1n Device Number
01001100 4C XG Model ID
00000000 00 Address High
00000000 00 Address Mid
01111110 7E Address Low
00000000 00 Data
11110111 F7 End of Exclusive
When this data is received, the MU10 will switch
to XG mode and all the parameters will be
initialized accordingly, and XG-compatible
messages such as NRPN and Bank Select messages
can be received. However, A/D part parameter
settings except Variation Send value will be
preserved (Variation Send will be initialized to the
value of 0).
Since approximately 50ms is required to execute
this message, be sure to leave an appropriate
interval before the subsequent message.
PERFORMANCE MODE CHANGE
(XG mode / TG300B mode)
XG System On = F0 43 1n 4c 00 00 7E 00 F7
TG300B Reset = F0 41 1n 42 12 40 00 7F 00
41 F7
n = device number
2.1.4.2 XG System Data parameter change