User Guide

51
Effect Parameter List
1 Reverb Time 0.3 ~ 30.0s 0-69 table#4
2 Diffusion 0 ~ 10 0-10
3 Initial Delay 0 ~ 63 0-63 table#5
4 HPF Cutoff Thru ~ 8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k ~ Thru 34-60 table#3
6
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11 Rev Delay 0 ~ 63 0-63 table#5
12 Density 0 ~ 3 0-3
13 Er/ Rev Balance E63> R ~ E=R ~ E<R63 1-127
14
15 Feedback Level -63 ~ +63 1-127
16
No. * Parameter Range Value P54**
Control
HALL1,2, ROOM1,2,3 ,STAGE1,2, PLATE
1 Lch Delay1 0.1 ~ 355.0ms 1-3550
2 Lch Feedback Level -63 ~ +63 1-127
3 Rch Delay1 0.1 ~ 355.0ms 1-3550
4 Rch Feedback Level -63 ~ +63 1-127
5 High Damp 0.1 ~ 1.0 1-10
6 Lch Delay2 0.1 ~ 355.0ms 1-3550
7 Rch Delay2 0.1 ~ 355.0ms 1-3550
8 Delay2 Level 0 ~ 127 0-127
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11
12
13 EQ Low Frequency 50Hz ~ 2.0kHz 8-40 table#3
14 EQ Low Gain -12 ~ +12dB 52-76
15 EQ High Frequency 500Hz ~ 16.0kHz 28-58 table#3
16 EQ High Gain -12 ~ +12dB 52-76
No. * Parameter Range Value P54**
Control
ECHO
1 Reverb Time 0.3 ~ 30.0s 0-69 table#4
2 Diffusion 0 ~ 10 0-10
3 Initial Delay 0 ~ 63 0-63 table#5
4 HPF Cutoff Thru ~ 8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k ~ Thru 34-60 table#3
6 Width 0.5 ~ 10.2m 0-37 table#8
7 Height 0.5 ~ 20.2m 0-73 table#8
8 Depth 0.5 ~ 30.2m 0-104 table#8
9 Wall Vary 0 ~ 30 0-30
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11 Rev Delay 0 ~ 63 0-63 table#5
12 Density 0 ~ 3 0-3
13 Er/ Rev Balance E63> R ~ E=R ~ E<R63 1-127
14
15 Feedback Level -63 ~ +63 1-127
16
No. * Parameter Range Value P54**
Control
WHITE ROOM ,TUNNEL, BASEMENT
1 L->R Delay 0.1 ~ 355.0ms 1-3550
2 R->L Delay 0.1 ~ 355.0ms 1-3550
3 Feedback Level -63 ~ +63 1-127
4 Input Select L,R,L&R 0-2
5 High Damp 0.1 ~ 1.0 1-10
6
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11
12
13 EQ Low Frequency 50Hz ~ 2.0kHz 8-40 table#3
14 EQ Low Gain -12 ~ +12dB 52-76
15 EQ High Frequency 500Hz ~ 16.0kHz 28-58 table#3
16 EQ High Gain -12 ~ +12dB 52-76
No. * Parameter Range Value P54**
Control
CROSS DELAY
1 Lch Delay 0.1 ~ 715.0ms 1-7150
2 Rch Delay 0.1 ~ 715.0ms 1-7150
3 Cch Delay 0.1 ~ 715.0ms 1-7150
4 Feedback Delay 0.1 ~ 715.0ms 1-7150
5 Feedback Level -63 ~ +63 1-127
6 Cch Level 0 ~ 127 0-127
7 High Damp 0.1 ~ 1.0 1-10
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11
12
13 EQ Low Frequency 50Hz ~ 2.0kHz 8-40 table#3
14 EQ Low Gain -12 ~ +12dB 52-76
15 EQ High Frequency 500Hz ~ 16.0kHz 28-58 table#3
16 EQ High Gain -12 ~ +12dB 52-76
No. * Parameter Range Value P54**
Control
DELAY L,C,R
1 Type S-H, L-H, Rdm, Rvs, Plt, Spr 0-5
2 Room Size 0.1 ~ 7.0 0-44 table#6
3 Diffusion 0 ~ 10 0-10
4 Initial Delay 0 ~ 63 0-63 table#5
5 Feedback Level -63 ~ +63 1-127
6 HPF Cutoff Thru ~ 8.0kHz 0-52
7 LPF Cutoff 1.0k ~ Thru 34-60
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11 Liveness 0 ~ 10 0-10
12 Density 0 ~ 3 0-3
13 High Damp 0.1 ~ 1.0 1-10
14
15
16
No. * Parameter Range Value P54**
Control
EARLY REF1,2
1 Lch Delay 0.1 ~ 715.0ms 1-7150
2 Rch Delay 0.1 ~ 715.0ms 1-7150
3 Feedback Delay 1 0.1 ~ 715.0ms 1-7150
4 Feedback Delay 2 0.1 ~ 715.0ms 1-7150
5 Feedback Level -63 ~ +63 1-127
6 High Damp 0.1 ~ 1.0 1-10
7
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11
12
13 EQ Low Frequency 50Hz ~ 2.0kHz 8-40 table#3
14 EQ Low Gain -12 ~ +12dB 52-76
15 EQ High Frequency 500Hz ~ 16.0kHz 28-58 table#3
16 EQ High Gain -12 ~ +12dB 52-76
No. * Parameter Range Value P54**
Control
DELAY L,R
1 Type TypeA,TypeB 0-1
2 Room Size 0.1 ~ 7.0 0-44 table#6
3 Diffusion 0 ~ 10 0-10
4 Initial Delay 0 ~ 63 0-63 table#5
5 Feedback Level -63 ~ +63 1-127
6 HPF Cutoff Thru ~ 8.0kHz 0-52
7 LPF Cutoff 1.0k ~ Thru 34-60
8
9
10 Dry/Wet D63>W ~ D=W ~ D<W63 1-127
11 Liveness 0 ~ 10 0-10
12 Density 0 ~ 3 0-3
13 High Damp 0.1 ~ 1.0 1-10
14
15
16
No. * Parameter Range Value P54**
Control
GATE REVERB,REVERSE GATE
: Can be controlled by AC1 (Assignable Controller 1)
No. * : These numbers correspond to the Parameter Suffix numbers in
<Table 1 - 3> (page 33)
ÆP54** : Refer to Effect Data Assign Table