Owner`s manual

File Utility RemotePerformance Song/Pattern
MX49/MX61 Reference Manual
Utility
General
MIDI
Controllers
Remote
Utility Job
QuickSeup
Factory Set
Version
66
CtrlReset
(Controller Reset)
Determines the status of the controllers (Modulation Wheel, Foot Controller, Knobs, etc.) when switching
between Voices. When this is set to “hold,” the controllers are kept at the current setting. When this is set to
“reset,” the controllers are reset to the default states (below).
Settings: hold, reset
If you select “reset,” the controllers will be reset to the following states/positions. As for controllers that are
not actually available on the instrument itself (for example, After Touch, Ribbon Controller, and Breath
Controller), these functions can be enabled by transmitting the corresponding MIDI control number from an
external MIDI controller.
Pitch Bend Center Ribbon Controller Center
Modulation Wheel Minimum Breath Controller Maximum
After Touch Minimum Assignable Function off
Foot Controller Maximum Expression Maximum
Footswitch off
MIDI Sync Determines whether Song/Pattern/Arpeggio playback will be synchronized to the instrument’s internal clock
or an external MIDI clock.
Settings: internal, external, auto
internal..... Synchronization to internal clock. You can use this setting when this tone generator is to be used
alone or as the master clock source for other equipment.
external.... Synchronization to a MIDI clock received from an external MIDI instrument via MIDI. Use this
setting when an external sequencer is to be used as the master.
auto..........When MIDI clock is transmitted continuously from an external MIDI device or computer, the
internal clock of the MX49/MX61 is automatically disabled and the MX49/MX61 is synchronized
with the external clock. When MIDI clock is not transmitted from the external MIDI device or
computer, the internal clock of the MX49/MX61 continues to run in sync with the latest received
tempo of the external MIDI device or computer (DAW software). This setting is useful when you
wish to alternate between external clock and internal clock.
NOTE
When setting the MX49/MX61 so that Song/Pattern/Arpeggio playback is synchronized to an external MIDI
clock, make sure to set the devices so that the MIDI clock from the DAW software/ external MIDI device is
properly transmitted to the MX49/MX61.
ClockOut
(MIDI Clock Out)
Determines whether MIDI clock (F8) messages will be transmitted via the MIDI OUT/USB terminal.
Settings: off, on
SeqCtrl
(Sequencer Control)
Determines whether or not Sequencer Control signals—start, continue and stop—will be received and/or
transmitted via MIDI.
Settings: off, in, out, in/out
off............. Not transmitted/recognized.
in..............Recognized, but not transmitted.
out............Transmitted, but not recognized.
in/out........ Transmitted/recognized.
BasicCh
(Basic Channel)
Determines the MIDI transmit/receive channel for an entire Performance.
Settings: 1 – 16, off
NOTE
The MIDI transmit/receive channel for Part 1–16 is fixed to 1 – 16 regardless of the “BasicCh” setting.
DeviceNo.
(Device number)
Determines the MIDI Device Number. This number must match the Device Number of the external MIDI
device when transmitting/receiving bulk data, parameter changes or other System Exclusive messages.
Settings: 1 – 16, all, off
RcvBulk
(Receive Bulk switch)
Determines whether or not Bulk Dump data can be received.
Settings: protect (not received), on (received)
BulkInterval
(Bulk Dump Interval)
Determines the interval time of the Bulk Dump transmission when the Bulk Dump function is used or a Bulk
Dump Request is received.
Settings: 0 – 900 ms
Parameter Description