User Manual

Chapter 3 Main Panel Window
DME Designer Owner’s Manual
57
Current Scene
Displays information about the current scene. You can switch between scenes.
[Change Display Scene]
Selects the information to be displayed. When “All” is selected scene link information is displayed
in [Scene Number] and [Scene Name]. When a DME group or SP2060 is selected scene
information is displayed in [Scene Number] and [Scene Name].
Refer to “Scene Manager” on page 82 for information on scenes, and “Scene Link Manager” on
page 151 for information on scene linking.
[Scene Number]
Displays the number of the current scene or scene link. A list where you can select a scene or
scene link is displayed when you press the []. The EDIT indicator will light when a parameter has
been edited after recalling or storing a scene.
[Scene Name]
Displays the name of the current scene or scene link.
[Scene Manager] Button
Opens the “Scene Manager” dialog box.
NOTE
Press <Ctrl> key and <+> key simultaneously recall the next scene and press <Ctrl> key and <-> key simultaneously recall
the previous scene. These settings can be changed via the Shortcut keys dialog box (page 156).
[Change displayed Scene]
(displays DME groups/SP2060s)
[Scene Number] [Scene Manager] Button[Scene Name]