SETTING-UP ADVICE
Setting-Up Advice
Earth connection
WARNING! THIS APPLIANCE MUST BE EARTHED.
The green and yellow wire of the mains cord must always be connected to an installation
safety earth or ground. The earth is essential for personal safety as well as the correct
installation of the system, and is internally connected to all exposed metal surfaces. Any
rack framework into which this unit may be mounted is assumed to be connected to the
same grounding circuit.
Mains setting
NEXO NXAMP Powered TDcontrollers exists under two references for NXAMP4x1 and three
references for NXAMP4x4:
NXAMP Reference Mains Voltage Mains current
NXAMP4x1U 100 to 120 Volts Max 20 Amps
NXAMP4x1C 220 to 240 Volts Max 10 Amps
NXAMP4x4U 100 to 120 Volts Max 2x 30 Amps
NXAMP4x4C 220 to 240 Volts Max 2x 16 Amps
110 to 120 Volts Max 2x 30 Amps
NXAMP4x4W
220 to 240 Volts Max 2x 16 Amps
Each model applies to various safety standards only when use with the correct mains
voltage. Therefore, the amplifier won’t start (or will stop working) if the mains voltage is
getting out of the following min and max limits:
NXAMP Reference Mains Minimum Voltage Mains Maximum Voltage
NXAMP4x1U or
NXAMP4x4U
60 Volts 150 Volts
NXAMP4x1C or
NXAMP4x4C
150 Volts 288 Volts