Operation Manual

Description of the Software Programs
18 NUAGE I/O (16D) / NUAGE I/O (16A) / NUAGE I/O (8A8D) Operation Manual
4 LPF1
Selects the type of low pass filter for the LFE channel.
5 LPF2
Selects the type of low pass filter for the LFE channel
which is sent the signal from each channel.
6 ATT1/2
Sets the attenuator for each channel. The setting range is
from 0dB to -12dB.
7 AMP
Sets the amplifier for the LFE channel. The setting range is
from 0dB to +12dB.
8 Block diagram
Indicates the position of each parameter in Bass
Management.
ATT & Delay Window
1 Presets
For selecting, storing, and deleting the preset.
2 Monitor
Selects the monitor for configuring the settings.
3 Mute on/off
Turns muting of the channel on and off.
4 Channel
Displays the channel.
5 Port
Displays the channel port.
6 ATT(dB)
Sets the attenuator/gain for speaker 1 and 2. The setting
range is from 0 dB to -12 dB, and the smallest unit is
0.1 dB.
7 DELAY(ms)
Sets the delay for the channel. The setting range is from 0
to 30 milliseconds, and the smallest unit is 0.02
milliseconds.
Option Description
THRU The filter is not applied.
80-24 A Butterworth filter with a cutoff frequency of
80 Hz and -24 dB of attenuation.
80-24L A Linkwitz filter with a cutoff frequency of
80 Hz and -24 dB of attenuation.
120-42 A Butterworth filter with a cutoff frequency of
120 Hz and -42 dB of attenuation.
Option Description
THRU The filter is not applied.
80-24 A Butterworth filter with a cutoff frequency of
80 Hz and -24 dB of attenuation.
80-24L A Linkwitz filter with a cutoff frequency of
80 Hz and -24 dB of attenuation.
MUTE The filter is muted.
1
2
45 736