Getting Started Guide

Appendix
14 NUAGE MASTER Getting Started
Specifying the Brightness
The way of specifying the brightness is the same as
“Adjusting the Touch Sensitivity” (page 13). When the
window is displayed, specify “Brightness.”
Calibrating Detection Point of
the Touch Screen
1. Turn on the device with [ALT] held down.
You can release [ALT] once the menu appears on
the [Multi function display].
2. Select “TOUCH PANEL CALIBRATION”
using the []/[] buttons on the right side
of the [Jog wheel] and then press [ENTER].
3. Select “YES” then press [ENTER].
4. Press and hold the symbol shown on-
screen.
When the next symbol is shown, press and hold it.
This procedure must be repeated several times.
5. When adjustment is complete, the display
will return to the top menu. Select “EXIT”
and press [ENTER].
The Nuage Master will restart.
The adjustments are now completed.
Resetting to the Factory
Default Condition
NOTE
Resetting the device to the factory default condition has no effect
on Nuendo or Nuendo projects that you have created.
The procedure for resetting the device to the factory
default condition (i.e., initialization) is similar to that
described above in “Calibrating Detection Point of the
Touch Screen”. In this case, however, you should select
“INITIALIZE MEMORIES” when the menu appears. When
the device has been reset, the display will return to the
menu. Select “EXIT” and press [ENTER].
Option Description
LED Low
Specifies the brightness of the button when
dim.
LED High
Specifies the brightness of the button when
lit.
OLED
Specifies the brightness of organic EL
display in both CHANNEL STRIP section on
Nuage Fader and CONTROL ROOM section
on Nuage Master.
LCD
Specifies the brightness of the [Multi function
display] on Nuage Master.