User Manual

Added functions in NUAGE V1.1 107
To use this function, make sure to perform the following:
Hardware connections
Setting up the serial port
Setting up the Nuage I/O
Hardware connections
Connect the AD8HR and Nuage I/O by AES/EBU, and
connect the AD8HR and a computer by the RS-232C
(cross cable).
Use a USB to Serial converter if there is no serial port in
your computer.
Setting up the serial port
Make the following serial port settings on your computer:
Instructions for making serial port settings are depend on
your particular computer (in Windows 7, for example,
right-click an applicable serial port on the “Device
Manager” to open the properties). Refer to the manual of
your computer for details.
Setting up the Nuage I/O
Open the “Nuage I/O Properties” from the NUAGE
Workgroup Manager, and then set the “ID” number of the
AD8HR.
The AD8HR can also be set up in NUAGE HA Remote
Setup. To open NUAGE HA Remote Setup, click the
Nuendo menu “Devices” “NUAGE HA Remote Setup.”
HA +48V Turns +48 V phantom power on and off. To
turn on phantom power, hold down the
[Multi function button A] for longer than two
seconds.
Parameter Value
Bits per second: 38400
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Operation Function
Computer
Nuage I/O
RS-232CAES/EBU
AD8HR