User Manual

3. Meter Control
[Usage Example]
Action Option #1 Option #2 min max Unit remarks
1
Start mtrstart
AMP:DigitalIn/Level Transmission Interval
-
40 10000 ms
2
Stop mtrstop
- -
-
-
-
3
Notification NOTIFY mtr
"level" dBFS level. (16 channels)
0 127 index * refer "Meter" table
4
Start
mtrstart
AMP:AnalogIn/Level Transmission Interval -
40 10000 ms
5
Stop mtrstop
- -
- - -
6
Notification NOTIFY mtr
"level"
dBFS level. (4 channels)
0 127 index * refer "Meter" table
7
Start mtrstart
PCD:Meter/Input/PostFader Transmission Interval -
40
10000 ms
8
Stop mtrstop
- -
- - -
9
Notification
NOTIFY mtr
"level" dBFS level. (20 channels)
0 127
index
* refer "Meter" table
10
Start mtrstart
PCD:Meter/MatrixOut/PreFader Transmission Interval -
40 10000 ms
11
Stop
mtrstop
-
-
- - -
12
Notification NOTIFY mtr
"level" dBFS level. (8 channels)
0
127 index * refer "Meter" table
13
Start mtrstart
PCD:Meter/MatrixOut/PostFader Transmission Interval -
40 10000 ms
14
Stop mtrstop
- -
- -
-
15
Notification NOTIFY mtr
"level" dBFS level. (8 channels)
0 127 index * refer "Meter" table
16
Start
mtrstart
PCD:Meter/Volume/PreFader Transmission Interval
-
40 10000 ms
17
Stop mtrstop
- -
-
- -
18
Notification NOTIFY mtr
"level" dBFS level. (4 channels)
0 127 index * refer "Meter" table
19
Start mtrstart
PCD:Meter/Volume/PostFader
Transmission Interval -
40 10000
ms
20
Stop mtrstop
- -
- - -
21
Notification
NOTIFY mtr
"level"
dBFS level. (4 channels)
0 127 index * refer "Meter" table
22
Start mtrstart
PCD:Meter/PeakLimit/GR Transmission Interval -
40
10000 ms
23
Stop mtrstop
- -
- - -
24
Notification NOTIFY mtr
"gr" dBFS level. (4 channels)
0 127
index
* refer "Meter" table
25
Start mtrstart
PCD:Meter/PeakLimit/Status Transmission Interval -
40 10000 ms
26
Stop
mtrstop
-
-
- - -
27
Notification NOTIFY mtr
"raw" Status (4 channels)
0 1 0: Inactive
1: Active
28
Start mtrstart
PCD:Meter/RMSLimit/GR Transmission Interval -
40 10000 ms
29
Stop
mtrstop
-
-
- - -
30
Notification NOTIFY mtr
"gr" dBFS level. (4 channels)
0 127 index * refer "Meter" table
31
Start mtrstart
PCD:Meter/RMSLimit/Status Transmission Interval -
40 10000 ms
32
Stop mtrstop
- -
-
-
-
33
Notification NOTIFY mtr
"raw" Status (4 channels)
0 1 0: Inactive
1: Active
34
Start mtrstart
AMP:Ch/SPLimit Transmission Interval -
40 10000 ms
35
Stop mtrstop
- -
- - -
36
Notification NOTIFY mtr
"raw" Status (4 channels)
0 1 0: Inactive
1: Active
37
Start mtrstart
AMP:Ch/OutputVoltage Transmission Interval -
40 10000 ms
38
Stop mtrstop
- -
- - -
39
Notification NOTIFY mtr
"level" dBFS level. (4 channels)
0 127 index * refer "Meter" table
40
Start mtrstart
PCD:Meter/AmpCh/VoltageRMS Transmission Interval -
40 10000 ms
41
Stop mtrstop
- -
- - -
42
Notification NOTIFY mtr
"level" dBFS level. (4 channels)
0 127 index * refer "Meter" table
43
Start mtrstart
AMP:Ch/OutputCurrent Transmission Interval -
40 10000 ms
44
Stop mtrstop
- -
- - -
45
Notification NOTIFY mtr
"level" dBFS level. (4 channels)
0 127 index * refer "Meter" table
46
Start mtrstart
PCD:Meter/AmpCh/CurrentRMS
Transmission Interval -
40
10000 ms
47
Stop mtrstop
- -
- - -
48
Notification NOTIFY mtr
"level" dBFS level. (4 channels)
0 127 index * refer "Meter" table
49
Start mtrstart
AMP:Ch/Limit Transmission Interval -
40 10000 ms
50
Stop mtrstop
- -
- - -
51
Notification NOTIFY mtr
"raw" Status (4 channels)
0
1 0: Inactive
1: Active
52
Start mtrstart
AMP:Ch/Protect Transmission Interval -
40 10000 ms
53
Stop mtrstop
- -
- - -
54
Notification NOTIFY mtr
"raw" Status (4 channels)
0 1 0: Inactive
1: Active
55
Start mtrstart
AMP:Meter/DanteOut Transmission Interval
-
40 10000 ms
56
Stop
mtrstop
- -
- - -
57
Notification NOTIFY mtr
"level" dBFS level. (16 channels)
0 127 index * refer "Meter" table
GR
Status
SP
Processor
RMS Limiter
GR
Peak Limiter
Status
Peak
RMS
Status
Voltage
Amp
Output Port
Peak
RMS
Dante
Current
Status
Limit
Protect
Volume
Pre
Post
Case
Command
Target Meter
Dante
Analog
Input
Output
Matrix
Input Port
Mixer
No.
Parameter
Address
To start meter data
transmission
mtrstart AMP:AnalogIn/Level 50
OK mtrstart AMP:AnalogIn/Level
To stop meter data
transmission
mtrstop AMP:AnalogIn/Level
OK mtrstop AMP:AnalogIn/Level
Meter data periodically sent
from device
NOTIFY mtr AMP:DigitalIn/Level 00 23 14 3f 54 22 …