SEVERITY Content Action
63 Firmware Versions
Mismatch
- ERROR The version of this
unit’s firmware is
not compatible
with the version of
the Dante
firmware.
The updater
provided on the
website contains
the firmware for
this unit and the
Dante firmware as
a set. Update both.
64 Dante Is Not
Working By Giga
Bit
DANTE NOT
GIGABIT
ERROR The network is not
connected at 1 GB.
In Daisy Chain
mode, this alert
also occurs when
connected to the
Control Port.
If this unit is
disconnected from
the network, alert
69 occurs, and this
alert is temporarily
cleared.
Use a 1GB network
switch.
65 Dante Is Working
At Secondary
WORK AT
SECONDARY
WARNING In Redundant
mode, Dante audio
communication is
occurring on the
Secondary circuit.
If this unit is
disconnected from
the network, alert
69 occurs, and this
alert is temporarily
cleared.
Check whether the
primary circuit may
have
malfunctioned.
66 Error Occurred At
Secondary Port
ERROR AT
SECONDARY
WARNING In Redundant
mode, the Dante
Primary circuit is
operating correctly,
but the Secondary
circuit is not
connected.
* Only if
connection had
once been
confirmed, and
then been
disconnected
If connection of
the Secondary
circuit is needed,
check whether it
may have
malfunctioned.
67 Wrong Word Clock WRONG WORD
CLOCK
WARNING A problem was
detected in the
word clock.
- In Dante
Controller,
correctly set the
word clock of the
entire system.
- Make sure that
the Fs (sampling
frequency) setting
is the same for the
devices whose
audio is patched.