User Manual

Number
Alert
Message
Log
Message
SEVERITY Content Action
68 Unit ID Mismatch - ERROR The UNIT ID and
the Dante Device
Label do not
match.
Defeat restrictions
such as the Dante
Device Lock
function and the
Dante Domain
Manager function,
and then change
the UNIT ID.
69 Dante Port Is Not
Connected
DANTE PORT IS
NOT CONNECTED
WARNING In Redundant
mode, the Dante
Primary circuit is
operating correctly,
but the Secondary
circuit is not
connected.
* This is displayed
only if connection
had once been
confirmed, and
then been
disconnected.
Make sure that the
Dante circuit is
correctly
connected.
shows the channel name (1-4, A-D)
 Sync Message
ID * Message Description Possible Solution
- NORMAL Operating normally -
- NOT READY The Dante module is being
prepared.
Wait until startup or synchronization is
completed. It may take up to 45 seconds
for this to be completed.
E01-03 WRONG WORD
CLOCK!
The word clock setting is
incorrect.
On the DanteÊController, set the clock
master and the sampling frequency
correctly.
E01-04 DANTE PORT DOES
NOT HAVE
CONNECTION!
The Dante network is not
connected.
Check whether an Ethernet cable might be
disconnected or broken.
E01-05 DANTE
CONNECTION
ERROR!
Other Dante devices cannot be
found because the Dante
network connections are
incorrect.
Check whether the Ethernet cable
connections are correct.
E01-06 DANTE IS NOT
WORKING BY GIGA
BIT!
A device that does not support
gigabit Ethernet is connected.
If you are conveying audio via Dante, use
devices that support gigabit Ethernet.
E01-07 DANTE IS WORKING
AT SECONDARY!
In the case of a redundant
network, communication is
occurring via the [SECONDARY]
port.
Check the circuit that is connected to the
[PRIMARY] port.
E01-08 ERROR OCCURRED
AT SECONDARY
PORT!
In the case of a redundant
network, a problem has
occurred in the circuit that is
connected to the [SECONDARY]
port.
Check the circuit that is connected to the
[SECONDARY] port.
- DANTE WORD
CLOCK MASTER
Functioning correctly as the
word clock master.
This indicates that the device is the word
clock master.
13. Reference
PC412-D PC412-DI PC406-D PC406-DI Owner’s Manual | 81