User Manual

MIDI Data Format
55
n=0-15(Device Channel
No.1-16)
GROUP ID 00111110 3e MODEL ID(digital mixer)
MODEL ID 00001001 09 Device code(PM1D)
PARAM TYPE 00000000 00 Current Memory
DATA 0ttttttt dd0 data type
0aaaaaaa dd1 addressHIGH(BIT13-7)
0aaaaaaa dd2 addressLOW(BIT6-0)
0ddddddd dd3 data
:
0ddddddd ddn
EOX 11110111 F7 End of Exclusive
Data type:
The “data” field contains the requested number of data bytes from the
requested address, converted from 8-bit to 7-bit form. The MSB's for
seven bytes will be the first byte of data.
Example) [seven bytes of 8 bit data] [8 bytes of 7 bit data]
80 01 82 03 84 05 06 54 00 01 02 03 04 05 06
The “data type” is the same as for a Parameter Value Request.
PARAMETER CHANGE (type 0x02:function call)
<Transmission>
If transmission is ON for Control Change ASSIGN or NRPN, this
message is transmitted when an operation causing multiple parameters
to be modified simultaneously is performed. This message is not
received.
STATUS 11110000 F0 System Exclusive Message
ID No. 01000011 43 Manufacture's ID
No.(YAMAHA)
SUB STATUS 0pppnnnn 1n response for request
n=0-15(Device Channel
No.1-16)
GROUP ID 00111110 3e MODEL ID(digital mixer)
MODEL ID 00001001 09 Device code(PM1D)
PARAM TYPE 00000010 02 function call
DATA 0ttttttt dd0 function
0aaaaaaa dd1 category/number
0aaaaaaa dd2 channel/number2
0ddddddd dd3 type
EOX 11110111 F7 End of Exclusive
function category/number number2,channel
--------------------------------------------------------------
0x04 EFF Lib Recall LIB No.Bit7-1 LIB No..Bit0,
EFF No.0-7
(LIB No.1-199, EFF No.0-7)
0x04 EFF Copy No.Bit7-1 No.Bit0, EFF
No.0-7
(No.255, EFF No.0-7)
0x05 GEQ Recall Category Library 126 GEQ No.0-23
0x05 GEQ Copy,Link No.127 GEQ No.0-23
0x06 IN EQ Lib Recall Category Library 126 CH No.0-111
0x06 IN EQ Copy Category Copy 127 CH No.0-111
0x07 OUT EQ Lib Recall Category Library 126 CH No.0-73
0x07 OUT EQ Copy Category Copy 127 CH No.0-73
0x08 IN GATE Lib Recall Category Library 126 CH No.0-111
0x08 IN GATE Copy Category Copy 127 CH No.0-111
0x09 IN COMP Lib Recall Category Library 126 CH No.0-111
0x09 IN COMP Change Category Copy 127 CH No.0-111
0x0a OUT COMP Lib RecallCategory Library 126 CH No.0-73
0x0a OUT COMP Change Category Copy 127 CH No.0-73
0x0b IN CH Lib Recall Category Library 126 CH No.0-111
0x0c OUT CH Lib Recall Category Library 126 CH No.0-73
0x0d IN CH COPY Source CH No.0-111 Destination CH
No.0-111,127 *1
0x0e OUT CH COPY Source CH No.0-73 Destination CH
No.0-73,127 *1
0x0f IN CH PAIR/LR-MONO *2 CH No.0-111
0x10 OUT CH PAIR *2 CH No.0-73
0x11 SETUP CHANGE 127 0
(*1 Since multiple destination channels are possible when using
the CH COPY function of the LCD, this will be 127 (fixed)
instead.
*2 0:PAIR L->R, 1:PAIR R->L, 2:RESET BOTH, 3:PAIR RELEASE
4:L-MONO, 5:R-MONO, 6:LR-MONO, 7:L,R,LR-MONO RELEASE )
type For EFF BIT5-0:EFFECT TYPE
For GEQ BIT6:MONO/LINK
For EQ, GATE, COMP, CH, COPY, PAIR
BIT6:MONO/PAIR, BIT5-3:reserved
BIT2:GATE TYPE, BIT1, 0:COMP TYPE
For SETUP 0:LOAD,
1:RECALL SAFE INPUT ALL ON,
2:RECALL SAFE INPUT ALL OFF,
3:RECALL SAFE OUTPUT ALL ON,
4:RECALL SAFE OUTPUT ALL OFF
EFF LIBRARY are transmitted when you recall a number that is not
assigned to a program change.