User Manual

Chapter 9. Recall safe/Mute safe
107
If Recall Safe is specified for either (not both) the
odd-numbered or even-numbered channel of two
channels, and you recall a scene in which these two
channels are paired, pairing will be forcibly
defeated, and the channel that was set to Recall Safe
will maintain the state prior to the recall.
Using the screen to set/defeat Recall Safe
Recall Safe can also be set/cancelled from within the display. With this method, you can not only set/cancel Recall Safe,
but also select the parameters to which Recall Safe will apply. Furthermore, you can select not only input channels or
output channels, but also DCA groups, internal effects, graphic EQ, and mute masters as objects for the recall.
[Procedure]
1. In the LCD FUNCTION ACCESS block, press the
[SCENE] switch several times to access the follow-
ing RECALL SAFE screen (SCENE function).
RECALL SAFE screen (SCENE function)
2. Of the buttons arranged in the screen, turn on the
SAFE ON/OFF buttons for the channels/parame-
ters that you wish to set to Recall Safe.
In the RECALL SAFE screen, click the SAFE ON/
OFF buttons to select the channels/parameters that
you wish to set to Recall Safe. The following elements
correspond to each button.
CH 1–96 {1-48} ........Input channels 1–96 {1–48}
ST IN 1–8 {1–4}........ST IN channels 1–8 {1–4}
MIX 1–48..................MIX channels 1–48
MTRX 1–24 ..............MATRIX channels 1–24
ST A/B ...................... STEREO A/B channels
DCA 1–12 ................ DCA groups 1–12
GEQ 1–24................. Graphic EQ modules 1–24
EFFECT 1–8............. Internal effects 1–8
MUTE MASTER...... Turn all mute groups on/off
For the INPUT, ST IN, MIX, MTRX, and STEREO
A/B channels, you can specify Recall Safe not only for
the entire channel, but for individual parameters.
The following parameters can be selected.
ALL..................All parameters of that channel
AT T ..................The ATT parameter of that channel
EQ....................The EQ parameters of that channel
(except ATT)
FADER ............The fader of that channel (includes
BALANCE for STEREO A/B)
SEND/TO MTRX .... The SEND/TO MATRIX
parameters of that channel
(ON, LEVEL, PAN, PRE/
POST, PAN, PRE POINT)
UNIT ........................ The parameters of the unit
patched to that channel (HA
GAIN GANG and HA A/B
LINK are included in ALL)
Hint
By clicking one of the SET ALL buttons located at the
bottom of the screen, you can set all channels, all
specified parameters, or all units to Recall Safe status.
If the SET ALL button is on, all units (including
those not displayed in this screen) will be set to
Recall Safe. Be aware that units that are not currently
patched and units that are patched to Insert will also
be set to Recall Safe.
Simply turning on the above buttons does not enable
the Recall Safe function. To enable Recall Safe, you
must turn on the SAFE ON/OFF button for the cor-
responding channel.
As an exception to this, Unit Recall Safe is indepen-
dent of Channel Recall Safe. For this reason, simply
turning on the UNIT button will exclude the corre-
sponding unit from recall operations even if the
SAFE ON/OFF button is off.
Channels/parameters whose buttons are turned on will
be set to Recall Safe. With this setting, these channels/
parameters will not be affected even if a scene is recalled.
LCD FUNCTION ACCESS
block
[SCENE] switch