User Manual

CS1D Operating Manual (Basic Operation)
152
Output channel metering point
Here’s how to set the metering point for the various output levels displayed in the meter bridge block.
[Procedure]
1. In the LCD FUNCTION ACCESS block, press the
[METER] switch several times to access the MIX 1-
48 screen or the MATRIX 1-24/ST/MONITOR IN5-
8 screen.
MATRIX 1-24/ST/MONITOR screen (METER
function)
The MIX 1-48 screen and MATRIX 1-24/ST/MONI-
TOR IN 5-8 screen show virtual level meters that
indicate the output levels of the output channels,
monitor outputs, and cue outputs. In this screen you
can also select the metering point for the output
channels.
2. Use the buttons located at the right of the screen to
select the metering point at which the output level
will be detected.
The following metering points can be selected.
PRE EQ ...............Immediately before the EQ
PRE FADER........Immediately before the fader
POST FADER.....Immediately after the fader
POST ON............After the [ON] switch
Hint
You can also use the METER [PRE] switch in the
METER section (MASTER block) of the CS1D to
select the metering point for the output channels.
If the METER [PRE] switch is on, either PRE EQ or
PRE FADER as selected in the display will be the
metering point.
If the METER [PRE] switch is off, either POST
FADER or POST ON as selected in the display will be
the metering point.
3. If you want the peak level display of the output
channels to be held, turn on the PEAK HOLD but-
ton.
Hint
You can also use the METER [PEAK HOLD] switch
in the METER section (MASTER block) of the CS1D
to turn peak hold on/off for the output channels.
LCD FUNCTION ACCESS
block
[METER] switch